Research Article
Research on DSP-based data model identification and triple-loop PID control of electro-hydraulic actuators
Abstract
This paper focuses on the electro-hydraulic actuator of a certain type of aircraft, detailing the DSP-based hardware structure and principles. The study utilizes data acquisition and data model identification to establish a second-order model for the electro-hydraulic actuator. Verification sets and mean squared error (MSE) calculations, with an MSE value of 0.0110, indicate a reasonable identification model. Subsequently, a controller design structure is proposed based on the identified model. Finally, simulations validate the identified model and the triple-loop PID control. Experimental results show that the system's sine response output amplification factor is 0.9242.
Keywords: DSP; Electro-hydraulic actuator; Model identification; Triple-loop control; PID
References
- Guo, Y. G., Zhao, H. L., & Zhu, B. (2020). Design of high reliable steering gear controller based on DSP. Electric Drive, 50(7), 74-78.
- Chen, H. M., Zhuang, H. Y., Ma, S. H., & Shi, X. T. (2014). Model identification of electromechanical actuator based on tests. Aeronautical Computing Technique, 44(04), 6-9.
- Tian, Z., Li, Y. Y., Han, S., Bu, C. G., & Liu, T. (2016). Study of identification for nonlinear system of electronic actuator. Computer Measurement & Control, 24(05), 110-112+116.
- Jia, J. T., Cui, Y. L., & Feng, Z. L. (2019). Model identification for electromechanical actuator based on dSPACE. Automobile Applied Technology, (10), 97-99.
- Zhou, W., Yang, S. X., & Zhao, L. Y. (2017). Retuning the actuator proportional-integral-derivative controller of spinning missiles. Journal of Aerospace Engineering, 231(14), 2594-2602.
- Hu, Q., Zhang, J., Yu, D. M., & Cui, J. F. (2007). Velocity control for rope-less elevator using permanent magnet linear synchronous motor with adaptive fuzzy PID. In Automation and Logistics, 2007 IEEE International Conference on (pp. 2361-2366).
- Liu, Z. Y., & Song, X. E. (2019). Rolling controlled trajectory correction fuze electromechanical actuator system simulation. Ship Electronic Engineering, 39(3), 93-97.
- Espinosa, A. G., Ruiz, J. R. R., Cusido, J., et al. (2008). Sensorless control and fault diagnosis of electromechanical contactors. IEEE Transactions on Industrial Electronics, 55(10), 3742-3750.
- Peng, J. Z., & Rickey, D. (2011). Identification and adaptive neural network control of a DC motor system with dead-zone characteristics. ISA Transactions, 50(4), 588-598.
- Yang, Y., Wang, M. G., & Yan, J. (2010). A better non-linear PID controller of digital electromechanical actuator system. Journal of Northwestern Polytechnical University, 28(3), 323-326.
- Fu, Y., & Li, B. (2022). Saturation constraint one-step optimal control of electrode current for the fused magnesia smelting process. Acta Automatica Sinica, 48(1), 239-248.