Design and Construction of Experimental System for Validation of a New Image Reconstruction Technique with Limited-view-angle Projection Data for BNCT-SPECT
Abstract
Boron Neutron Capture Therapy (BNCT) is expected to be a promising radiation therapy for cancer, and research on various issues associated with it is still in progress. One of the unsolved issues is the construction of a system for observing the effect of the treatment (local boron dose) in real time under high-background circumstances. Thus, we set out to establish a method for measuring gamma-rays emitted promptly from the body following the boron neutron capture reaction and reconstructing images in a SPECT-like manner. We call this method BNCT-SPECT. We have been developing a new image reconstruction method based on Bayesian estimation for the BNCT-SPECT method. In the present study, the aims were to design and construct an experimental system capable of validating BNCT-SPECT and its image reconstruction method and to confirm BNCT-SPECT’s performance. The crucial takeaway from this study is that we should consider the use of extremely high background radiation during BNCT. For the validation of BNCT-SPECT, we attempted to reproduce these conditions, despite this being quite challenging. We first constructed an experimental system capable of reproducing such conditions. Theoretical investigation was carried out to facilitate the design of the system using the Monte Carlo transport calculation code MCNP. Finally, we performed experiments with some standard gamma-ray sources to complete the system.
References
- Ministry of Health, Labour and Welfare of Japan, “Annual Health, Labour and Welfare Report 2021” ,2023, https://www.mhlw.go.jp/toukei/saikin/hw/jinkou/kakutei21/dl/11_h7.pdf
- U.S. Department of Health and Human Services, National Institutes of Health, National Cancer Institute, 2020, https://www.cancer.gov/about-cancer/treatment/types
- Menéndez, P. R., Roth, B. M. C., Pereira, M. D., Casal, M. R., González, S. J., Feld, D. B.,Santa Cruz, G.A.,Kessler, J.,Longhino, J.,Blaumann, H.,et al. “BNCT for skin melanoma in extremities: updated Argentine clinical results. Applied Radiation and Isotopes”, 67(7-8),(2009): S50-S53.
- Kankaanranta, L., Seppälä, T., Koivunoro, H., Saarilahti, K., Atula, T., Collan, J., Salli, E., Kortesniemi, M., Uusi-Simola, J., Mäkitie, A., et al. "Boron neutron capture therapy in the treatment of locally recurred head and neck cancer." International Journal of Radiation Oncology* Biology* Physics 69.2 (2007): 475-482.
- Fairchild, R. G., and V. P. Bond. "Current status of 10B-neutron capture therapy: enhancement of tumor dose via beam filtration and dose rate, and the effects of these parameters on minimum boron content: a theoretical evaluation." International Journal of Radiation Oncology* Biology* Physics 11.4 (1985): 831-840.
- Verbakel, W. F., Sauerwein, W., Hideghety, K., & Stecher-Rasmussen, F. "Boron concentrations in brain during boron neutron capture therapy: in vivo measurements from the phase I trial EORTC 11961 using a gamma-ray telescope." International Journal of Radiation Oncology* Biology* Physics 55.3 (2003): 743-756.
- Fantidis, J. G., Saitioti, E., Bandekas, D. V., & Vordos, N. Optimised BNCT facility based on a compact DD neutron generator. International Journal of Radiation Research, 11(4), (2013): 207.
- Sauerwein, W. A., Wittig, A., Moss, R., & Nakagawa, Y. (2012). Neutron capture therapy: principles and applications. Springer Science & Business Media.
- Manabe, M., Nakamura, S., Murata, I. "Study on measuring device arrangement of array-type CdTe detector for BNCT-SPECT". Reports of Practical Oncology & Radiotherapy, 2016, 21(2): 102-107.
- Lee, P. Y., Liu, Y. H., & Jiang, S. H. Dosimetric performance evaluation regarding proton beam incident angles of a lithium-based AB-BNCT design. Radiation protection dosimetry, 161(1-4),(2014): 403-409.
- Haruka, I., Shuto, T., Fan, L., Yuri, M., Singo, T., Sachie, K., Fuminobu, S., Isao, M.“A New Image Reconstruction Technique with Limited View-angle Projection Data for BNCT-SPECT”. In 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), (2020): (pp. 1-4).
- C&A, 2012. Crystals and Applications. https://www.c-and-a.jp/company.html/, 1st, September 2020.
- Japanese Society of Neutron Capture Therapy (JSNCT), 2018. The 15th Congress on Neutron Capture Therapy. Hokkaido University, Japan. Sept. 1–2, 2018.
- Lemmel, H.D., McLaughlin, P.K., Pronyaev, V.G., 2001. ENDF/B-VI Release 8 (Last release of ENDF/B-VI) The U.S. Evaluated Nuclear Data Library for Neutron Reaction Data, IAEA-NDS-100, Rev. 11.
- Murata, I., Kusaka, S., Minami, K., Saraue, N., Tamaki, S., Kato, I., Sato, F. "Design of SPECT for BNCT to measure local boron dose with GAGG scintillator". Applied Radiation and Isotopes, 2022, 181: 110056.
- Jaszczak, R. J., Coleman, R. E., Lim, C. B. "SPECT: Single photon emission computed tomography[J]". IEEE Transactions on Nuclear Science, 1980, 27(3): 1137-1153.
- IAEA, 2020. Virtual Technical Meeting on Advances in Boron Neutron Capture Therapy.EVT1905174. https://nucleus.iaea.org/sites/accelerators/TMBNCT/SitePages/Home.aspx, 22nd September 2020.
- Hales, B., Katabuchi, T., Igashira, M., Terada, K., Hayashizaki, N., & Kobayashi, T. "Predicted performance of a PG-SPECT system using CZT primary detectors and secondary Compton-suppression anti-coincidence detectors under near-clinical settings for boron neutron capture therapy." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 875 (2017): 51-56.
- Ishikawa, M., Kobayashi, T., Sakurai, Y., & Kanda, K. "Optimization technique for a Prompt Gamma-ray SPECT collimator system." Journal of radiation research 42.4 (2001): 387-400.
- Kobayashi, T., Sakurai, Y., & Ishikawa, M.. "A noninvasive dose estimation system for clinical BNCT based on PG‐SPECT—Conceptual study and fundamental experiments using HPGe and CdTe semiconductor detectors". Medical physics, 27(9), (2000): 2124-2132.
- af Rosenschöld, P. M., Minarik, D., Östlund, C., Ljungberg, M., & Ceberg, C. "Prompt gamma tomography during BNCT—a feasibility study." Journal of Instrumentation 1.05 (2006): P05003.
- Iwasaki, S. “A new approach for unfolding problems based only on the Bayes’ Theorem” Proceedings of the 9th International Symposium on Reactor Dosimetry (1997) pp.245-252.
- Minsky, D. M., Valda, A. A., Kreiner, A. J., Green, S., Wojnecki, C., & Ghani, Z.. First tomographic image of neutron capture rate in a BNCT facility. Applied Radiation and Isotopes, 69(12), (2011): 1858-1861.
- Iwasaki, S. “Solving method of Radiation Inverse Problems Based on the Iterative Bayes ’Estimation: Image Reconstruction Problem in CTs”, Journal Article, 02853604, 1996
- MCNP Team, 2005. MCNP5-1.40 RSICC Release Notes. LA-UR-05-8617.
- Photonics, Hamamatsu, 2017. Multi-Pixel Photon Counters (MPPCs/SiPMs). https://www. hamamatsu.com/jp/en/product/optical-sensors/mppc/mppc_mppc-array/index.html, 1st April 2017.
- Kanno, I., Nishimatsu, D., Funama, F. "Simulation study on the feasibility of current-mode SPECT for B-10 concentration estimation in boron neutron capture therapy." Journal of Instrumentation 14.02 (2019): C02002.
- Minami, K., Saraue1, N., Ohya, R., Sato, F., Murata, I., 2017. Design of a proto-type array detector using GAGG scintillator for BNCT-SPECT. Nov. 13-15, 2017. In: 9th Young Researchers’ BNCT Meeting (YBNCT 9). Uji Obaku Plaza, Kyoto. P8-3.