Research Article

Ultrashort Echo Time (UTE) Imaging for Contrast Agent Deposition Measurement: A Review

Xiao Xian*
School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China

* Corresponding author: [email protected]

Abstract

The deposition of Gadolinium-based contrast agents (GBCAs) has become a growing concern in the field of enhanced Magnetic Resonance Imaging (MRI). GBCAs have been found to be accumulate in various tissues, including the brain and bone, leading to potential long-term health risks, even in patients with normal renal function. Conventional MRI sequences are often limited in detecting Gd deposition in tissues like cortical bone due to their extremely short transverse relaxation times. Ultrashort Echo Time (UTE) MRI sequences offer a promising solution to this challenge by capturing signals from tissues with short relaxation times, enabling more accurate assessment of Gd deposition. This review provides a comprehensive overview of the application of UTE sequences in the measurement of Gd deposition, highlighting key advancements in the applications of UTE technique. It also explores the use of UTE imaging in combination with other methods. This review also discusses potential future directions and give some possible solutions.

Keywords: Ultrashort Echo Time (UTE) Imaging; Contrast Agent Deposition
Published: December 26, 2024
DOI: 10.54254/2753-8818/2024.18849
Volume: TNS Vol.72
pp. 27-31
Download PDF

References

  1. T. Grobner, “Gadolinium – a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?, ” Nephrol. Dial. Transplant., vol. 21, no. 4, pp. 1104–1108, Apr. 2006, doi: 10.1093/ndt/gfk062.
  2. A. Techawiboonwong, H. K. Song, and F. W. Wehrli, “In vivo MRI of submillisecond T 2 species with two‐dimensional and three‐dimensional radial sequences and applications to the measurement of cortical bone water, ” NMR Biomed., vol. 21, no. 1, pp. 59–70, Jan. 2008, doi: 10.1002/nbm.1179.
  3. M. D. Robson, P. D. Gatehouse, M. Bydder, and G. M. Bydder, “Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging:, ” J. Comput. Assist. Tomogr., vol. 27, no. 6, pp. 825–846, Nov. 2003, doi: 10.1097/00004728-200311000-00001.
  4. K. Zhao et al., “Detection of gadolinium deposition in cortical bone with ultrashort echo time T1 mapping: an ex vivo study in a rabbit model, ” Eur. Radiol., vol. 31, no. 3, pp. 1569–1577, Mar. 2021, doi: 10.1007/s00330-020-07258-x.
  5. Y.-D. Xiao, R. Paudel, J. Liu, C. Ma, Z.-S. Zhang, and S.-K. Zhou, “MRI contrast agents: Classification and application (Review), ” Int. J. Mol. Med., vol. 38, no. 5, pp. 1319–1326, Nov. 2016, doi: 10.3892/ijmm.2016.2744.
  6. M. Rasschaert, R. O. Weller, J. A. Schroeder, C. Brochhausen, and J.-M. Idée, “Retention of Gadolinium in Brain Parenchyma: Pathways for Speciation, Access, and Distribution. A Critical Review, ” J. Magn. Reson. Imaging, vol. 52, no. 5, 2020.
  7. N. Murata, K. Murata, L. F. Gonzalez-Cuyar, and K. R. Maravilla, “Gadolinium tissue deposition in brain and bone, ” Magn. Reson. Imaging, vol. 34, no. 10, pp. 1359–1365, Dec. 2016, doi: 10.1016/j.mri.2016.08.025.
  8. N. Murata et al., “Macrocyclic and Other Non–Group 1 Gadolinium Contrast Agents Deposit Low Levels of Gadolinium in Brain and Bone Tissue: Preliminary Results From 9 Patients With Normal Renal Function, ” Invest. Radiol., vol. 51, no. 7, pp. 447–453, Jul. 2016, doi: 10.1097/RLI.0000000000000252.
  9. E. Tedeschi et al., “In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents, ” Eur. Radiol., vol. 26, no. 12, pp. 4577–4584, Dec. 2016, doi: 10.1007/s00330-016-4245-2.
  10. R. A. Horch, J. S. Nyman, D. F. Gochberg, R. D. Dortch, and M. D. Does, “Characterization of 1 H NMR signal in human cortical bone for magnetic resonance imaging, ” Magn. Reson. Med., vol. 64, no. 3, pp. 680–687, Sep. 2010, doi: 10.1002/mrm.22459.
  11. M. L. Lord, D. R. Chettle, J. L. Gräfe, M. D. Noseworthy, and F. E. McNeill, “Observed Deposition of Gadolinium in Bone Using a New Noninvasive in Vivo Biomedical Device: Results of a Small Pilot Feasibility Study, ” Radiology, vol. 287, no. 1, pp. 96–103, Apr. 2018, doi: 10.1148/radiol.2017171161.
  12. D. Bageac et al., “MRI demonstration of gadolinium deposition in bone after monthly triple-dose gadopentetate dimeglumine and correlation with frequency of hypophosphatemia, ” Clin. Imaging, vol. 70, pp. 136–141, Feb. 2021, doi: 10.1016/j.clinimag.2020.07.022.
  13. X. Zhang et al., “Evaluation of gadolinium deposition in cortical bone using three‐dimensional ultrashort echo time quantitative susceptibility mapping: A preliminary study, ” NMR Biomed., vol. 37, no. 1, p. e5035, Jan. 2024, doi: 10.1002/nbm.5035.
  14. Y. Ma et al., “Trabecular bone imaging using a 3D adiabatic inversion recovery prepared ultrashort TE Cones sequence at 3T, ” Magn. Reson. Med., vol. 83, no. 5, pp. 1640–1651, May 2020, doi: 10.1002/mrm.28027.
  15. T. H. Darrah, J. J. Prutsman-Pfeiffer, R. J. Poreda, M. Ellen Campbell, P. V. Hauschka, and R. E. Hannigan, “Incorporation of excess gadolinium into human bone from medical contrast agents, ” Metallomics, vol. 1, no. 6, p. 479, 2009, doi: 10.1039/b905145g.
  16. A. V. Dimov, Z. Liu, P. Spincemaille, M. R. Prince, J. Du, and Y. Wang, “Bone quantitative susceptibility mapping using a chemical species–specific signal model with ultrashort and conventional echo data, ” Magn. Reson. Med., vol. 79, no. 1, pp. 121–128, 2018, doi: 10.1002/mrm.26648.
  17. S. Jerban et al., “Significant correlations between human cortical bone mineral density and quantitative susceptibility mapping (QSM) obtained with 3D Cones ultrashort echo time magnetic resonance imaging (UTE-MRI), ” Magn. Reson. Imaging, vol. 62, pp. 104–110, Oct. 2019, doi: 10.1016/j.mri.2019.06.016.