Research Article

Possible Improvements in the Precision of the Atom-interferometric Equivalence Principle Test by Reducing AC Stark Shift Uncertainty

Xinyi Liu*
Department of Physics, University of Washington, 3910 15th Ave. NE, WA 98105-1560, USA

* Corresponding author: [email protected]

Abstract

We discussed possible improvement methods for a dual-species atom interferometry test of the weak equivalence principle (WEP) at the 10^(-12) level. The original research tested the WEP by comparing the acceleration difference of the free-fallen rubidium isotopes atom clouds. Based on the percent uncertainty presented from this test, AC stark shift is the most significant obstacle to improving precision. This article will discuss a precision-improving method to the original test by suppressing the background AC stark shift by centering the interferometry lasers to their "magic frequency." The expected improved precision of the uncertainty level is below the 10^(-18) level. Due to the limitation of instruments, we have yet to test this improving method in the actual measurement. Still, we analyzed the possible difficulties in practical usage and discussed solving strategies that correspond to the problems.

Keywords: Equivalence principle; AC stark shift.
Published: May 25, 2023
DOI: 10.54254/2753-8818/5/20230576
Volume: TNS Vol.5
pp. 339-342
Download PDF

References

  1. Bonnin, A., Zahzam, N., Bidel, Y. and Bresson, A. (2015). Characterization of a simultaneous dual-species atom interferometer for a quantum test of the weak equivalence principle. Physical Review A, [online] 92(2). doi:10.1103/physreva.92.023626.
  2. Fray, S., Diez, C.A., Hänsch, T.W. and Weitz, M. (2004). Atomic Interferometer with Amplitude Gratings of Light and Its Applications to Atom Based Tests of the Equivalence Principle. Physical Review Letters, [online] 93(24). doi:10.1103/physrevlett.93.240404.
  3. Schuldt, T., Schubert, C., Krutzik, M., Bote, L.G., Gaaloul, N., Hartwig, J., Ahlers, H., Herr, W., Posso-Trujillo, K., Rudolph, J., Seidel, S., Wendrich, T., Ertmer, W., Herrmann, S., Kubelka-Lange, A., Milke, A., Rievers, B., Rocco, E., Hinton, A. and Bongs, K. (2015). Design of a dual species atom interferometer for space. Experimental Astronomy, [online] 39(2), pp.167–206. doi:10.1007/s10686-014-9433-y.
  4. Asenbaum, P., Overstreet, C., Kim, M., Curti, J. and Kasevich, M.A. (2020). Atom-Interferometric Test of the Equivalence Principle at the 10^-12 Level. Physical Review Letters, [online] 125(19). doi:10.1103/physrevlett.125.191101.
  5. Fasano, R.J.; Chen, Y.J., McGrew, W.F., Brand, W.J., Fox, R.W. and Ludlow, A.D. (2021). Characterization and Suppression of Background Light Shifts in an Optical Lattice Clock. Physical Review Applied, [online] 15(4). doi:10.1103/physrevapplied.15.044016.
  6. Keaveney, J., Hamlyn, W.J., Adams, C.S. and Hughes, I.G. (2016). A single-mode external cavity diode laser using an intra-cavity atomic Faraday filter with short-term linewidth <400 kHz and long-term stability of <1 MHz. Review of Scientific Instruments, [online] 87(9), p.095111. doi:10.1063/1.4963230.
  7. Häffner, H., Gulde, S., Riebe, M., Lancaster, G., Becher, C., Eschner, J., Schmidt-Kaler, F. and Blatt, R. (2003). Precision Measurement and Compensation of Optical Stark Shifts for an Ion-Trap Quantum Processor. Physical Review Letters, [online] 90(14). doi:10.1103/physrevlett.90.143602.