Research Article
Exploring the Relationship Between Muon Detection Rates and Atmospheric Pressure Using Cosmic Watch Detectors
Abstract
This study explores how atmospheric pressure affects muon detection rates. By analyzing data from six Cosmic Watch detectors, we organized the collected information, examined the correlation between atmospheric pressure and muon detection rates, and addressed the timing discrepancies across detectors. Our findings show that muon detection rates decrease as atmospheric pressure rises. The study also improves time difference correction methods, providing new strategies and tools for detecting rare coincidence events recorded by multiple detectors.
Keywords: muons; atmospheric pressure; cosmic rays; detection rates; time synchronization; coincidence events
References
- Abbasi, R. U., et al. Atmospheric Effects on Muon Rates at the Pierre Auger Observatory. Physical Review D, 86(3), 032007. (2012)
- Patrick, A., et al. “Muon Detection at Different Altitudes: A Study of Pressure Effects”. Astroparticle Physics, 114, 51-60. (2020). DOI: 10.1103/PhysRevD.91.032003
- S.N. Axani, et al. “The CosmicWatch Desktop Muon Detector: A self- contained, pocket-sized particle detector”. In: Journal of Instrumentation 13 (2018), DOI:10.1088/1748-0221/13/03/P03019.
- P. Lecoq. “Scintillation Detectors for Charged Particles and Photons”. In: Particle Physics Reference Library. 2020, pp. 45–89. DOI: 10.1007/978-3-030-35318-6_3.
- Abdullrahman H. Maghrabi1, et al. “The Role of Atmospheric Pressure, Temperature, and Humidity on Cosmic Ray Muons at a Low Latitude Station”. In: International Journal of Astronomy and Astrophysics 13 (2023). DOI: 10.4236/ijaa.2023.133014.