Abstract

This article will mainly introduce the application of applying medical imaging technology to assist in the identification of various biosensors (biomolecule).In today's cutting-edge cross field of medicine and biotechnology, the application of medical imaging technology to help the accurate identification of a variety of biosensors is showing great potential and value There are currently various mature and already put in use imaging technologies such as MRI, PET, etc. MRI uses powerful magnetic field and radio frequency pulse, which can obtain truly clear structural images of the human body; Pet can detect the positron annihilation signal generated by the decay of radioisotopes to monitor the metabolic activities in organisms with high sensitivity. More assistance is provided in identifying biometric components. The principle is to combine specific markers with sensors, and the combined system has specific properties such as radioactivity and magnetism that can be detected by medical imaging instruments. The review will talk about combine multiple technologies to identify biomolecule.

Keywords: Imaging; Recognition; Biosensors
Published: May 19, 2025
DOI: 10.54254/2753-8818/2025.23049
Volume: TNS Vol.97
pp. 106-112
Download PDF

References

  1. Chen K, Chen X. Design and development of molecular imaging probes[J]. Currenttopics in medicinal chemistry, 2010, 10(12): 1227-1236.
  2. DiFilippo F P. Instrumentation and principles of imaging: PET[M]//Cardiac PET andPET/CT Imaging. New York, NY: Springer New York, 2007: 3-18.
  3. Van Geuns R J M, Wielopolski P A, de Bruin H G, et al. Basic principles of magneticresonance imaging[J]. Progress in cardiovascular diseases, 1999, 42(2): 149-156.
  4. Louie A. MRI biosensors: A short primer[J]. Journal of Magnetic Resonance Imaging,2013, 38(3): 530-539.
  5. Charpentier C, Salaam J, Nonat A, et al. pH-Dependent Hydration Change in a Gd-Based MRI Contrast Agent with a Phosphonated Ligand[J]. Chemistry–A EuropeanJournal, 2020, 26(24): 5407-5418.
  6. Charpentier, Cyrille, et al. "Phosphonated Podand Type Ligand for the Complexationof Lanthanide CationsPhosphonated Podand Type Ligand for the Complexation ofLanthanide Cations."European Journal of Inorganic Chemistry 2019.16 (2019): 2168-2174.
  7. Aime, Silvio, et al. "A R2/R1 ratiometric procedure for a concentration-independent,pH-responsive, Gd (III)-based MRI agent."Journal of the American ChemicalSociety 128.35 (2006): 11326-11327.
  8. Nishie, Akihiro, et al. "In vitro and in vivo detection of drug-induced apoptosis usingAnnexin V-conjugated ultrasmall superparamagnetic iron oxide (USPIO): A pilotstudy."Magnetic Resonance in Medical Sciences 18.2 (2019): 142-149.
  9. Ruan, Dan, and Long Sun. "Amyloid-β PET in Alzheimer's disease: a systematic reviewand Bayesian meta-analysis."Brain and Behavior 13.1 (2023): e2850.
  10. Sander, Christin Y., Hanne D. Hansen, and Hsiao-Ying Wey. "Advances insimultaneous PET/MR for imaging neuroreceptor function."Journal of cerebral bloodflow & metabolism 40.6 (2020): 1148-1166.