Technological Innovations and Clinical Implementation of Continuous Glucose Monitoring (CGM) Systems
Abstract
Diabetes is a chronic and incurable metabolic disorder, necessitating rigorous blood glucose management as the cornerstone of effective treatment. Maintaining blood glucose levels within the normal range is critical for mitigating the risk of microvascular complications. Continuous glucose monitoring (CGM) systems represent a transformative advancement in glucose monitoring technology, enabling automated, real-time tracking of glycemic fluctuations by measuring interstitial fluid (ISF) glucose concentrations and converting these readings into blood glucose values.This paper provides a comprehensive overview of the development of CGM systems, reviewing their functional characteristics, target populations, and current technological advancements. Additionally, it examines the clinical evaluation framework for CGM systems and analyzes their application across diverse scenarios. Finally, the study highlights future directions and challenges in CGM technology, offering insights to guide further innovation and optimize clinical implementation.This review aims to serve as a valuable reference for researchers and clinicians in advancing next-generation CGM systems and enhancing their practical utility in diabetes management.
References
- Polonsky, K.S.. The past 200 years in diabetes [J]. The New England Journal of Medicine , 2012 , 367(14): 1332-1340.
- Diabetes Society of Chinese Medical Association Chinese Guidelines for the Prevention and Treatment of Diabetes (2024 Edition) [J]. Chinese Journal of Diabetes, 2025, 17(01): 16-139.
- Lee I, Probst D, Klonoff D, et al. Continuous glucose monitoring systems-Current status and future perspectives of the flagship technologies in biosensor research [J]. Biosensors and Bioelectronics, 2021, 181: 113054.
- Singh L G, Levitt D L, SatyarenggaATYARENGGA M, et al. Continuous Glucose Monitoring in General Wards for Prevention of Hypoglycemia: Results From the Glucose Telemetry System Pilot Study [J]. Journal of Diabetes Science and Technology, 2020, 14(4): 783-790.
- Chen Wei. Research on Subcutaneous Implantable Microsensor Technology for Continuous Glucose Monitoring [D]. Zhejiang University, 2018.
- Updike S J, Hicks G P. The enzyme electrode [J]. Nature, 1967, 214(5092): 986-988.
- JR L C C. Membrane polarographic electrode system and method with electrochemical compensation: US3539455A [P]. 1970-11-10 [2025-05-09].
- Wang J. Electrochemical Glucose Biosensors [J]. Chemical Reviews, 2008, 108(2): 814-825.
- Yamada S. Historical achievements of self-monitoring of blood glucose technology development in Japan [J]. Journal of Diabetes Science and Technology, 2011, 5(5): 1300-1306.
- Yamashita Y, Lee I, Loew N, et al. Direct electron transfer (DET) mechanism of FAD dependent dehydrogenase complexes ∼from the elucidation of intra- and inter-molecular electron transfer pathway to the construction of engineered DET enzyme complexes∼ [J]. Current Opinion in Electrochemistry, 2018, 12: 92-100.
- Vaddiraju S, Burgess D J, Tomazos I, et al. Technologies for continuous glucose monitoring: current problems and future promises [J]. Journal of Diabetes Science and Technology, 2010, 4(6): 1540-1562.
- Wang Chaoping, Yuan Xiaoli, Wang Min, et al. Research progress on the clinical application of remote continuous glucose monitoring [J]. Modern Clinical Nursing, 2023, 22(11): 82-88.
- HEALTH C for D and R. Eversense E3 Continuous Glucose Monitoring (CGM) System – P160048/S021 [J/OL]. FDA, 2023 [2025-05-09].
- Diabetes Society of Chinese Medical Association Diagnosis and Treatment Guidelines for Type 1 Diabetes mellitus in China (2021 Edition) [J]. Chinese Journal of Diabetes, 2022, 14(11): 1143-1250.
- 2. Diagnosis and Classification of Diabetes: Standards of Care in Diabetes—2025 | Diabetes Care | American Diabetes Association [EB/OL]. [2025-05-09].
- Lu Wudan, Liu Junxiang. Application of Continuous Glucose Monitoring System in Evaluating Islet Function of type 1 Diabetes Mellitus [J]. New World of Diabetes, 2024, 27(20): 184-187, 198.
- Diabetes Society of Chinese Medical Association Chinese Guidelines for the Prevention and Treatment of Type 2 Diabetes Mellitus (2020 Edition) [J]. Chinese Journal of Diabetes, 2021, 13(04): 315-409.
- Ping Yanru, Jia Zhumin, Huang Jiarong, et al. The application progress and prospect of continuous glucose monitoring in patients with type 2 diabetes mellitus [J]. Chinese Clinical Research, 2024, 37(7): 1008-1012.
- Turksoy K, Hajizadeh I, Hobbs N, et al. Multivariable Artificial Pancreas for Various Exercise Types and Intensities [J]. Diabetes Technology & Therapeutics, 2018, 20(10): 662-671.
- Priyadarshini R G, Narayanan S. Analysis of blood glucose monitoring – a review on recent advancements and future prospects [J]. Multimedia Tools and Applications, 2024, 83(20): 58375-58419.
- Villena G W, Mobashsher A T, Abbosh A. The Progress of Glucose Monitoring—A Review of Invasive to Minimally and Non-Invasive Techniques, Devices and Sensors [J/OL]. Sensors, 2019, 19(4): 800.
- Li Xiaolei, Qi Xiaoling, Xu Liwu, et al. Observation on the Therapeutic Effect of Continuous Glucose Monitoring System Combined with Insulin Pump in the Treatment of Newly diagnosed Type 2 Diabetes Patients [J]. Chinese Journal of Diabetes, 2016, 24(3): 219-222.
- Bergenstal R M, Klonoff D C, Garg S K, et al. Threshold-Based Insulin-Pump Interruption for Reduction of Hypoglycemia [J/OL]. New England Journal of Medicine, 2013, 369(3): 224-232.