Research Article

Biodegradable Metal Stents for Cardiovascular Diseases: Inflammation Modulation and Functional Optimization

Mingyue Wu*
Department of Biological Sciences, University of Bristol, Bristol, United Kingdom

* Corresponding author: [email protected]

Abstract

Cardiovascular diseases (CVDs) persist as the foremost global cause of morbidity and mortality, pushing the advancement of vascular implants designed to reestablish perfusion ability and promote vessel repair. However, conventional permanent stents often lead to long-term complications such as chronic inflammation, late thrombosis, and impaired vascular remodeling due to their persistent presence. Initial approaches applied pure biodegradable metals for stent fabrication; however, rapid corrosion, inadequate mechanical integrity, and slow degradation frequently constrained their clinical applicability. To address these limitations, biodegradable metal stents (BMSs) have emerged as next-generation alternatives, providing transient mechanical support that resorbs progressively upon fulfilling their therapeutic role, thereby reducing chronic body responses. Alloys based on magnesium, zinc, and iron have garnered significant interest owing to their unique corrosion kinetics, mechanical properties, and biocompatibility. This review outlines recent progress in BMS development, highlighting major strategies for performance enhancement—including compositional design to tailor intrinsic material behavior, microstructural engineering to optimize strength and ductility, surface modification to improve biocompatibility, and multifunctional interfaces to enable controlled degradation and biological modulation. By integrating material science and biomedical perspectives, this review aims to provide insights into current challenges and future directions for the clinical translation of BMSs.

Keywords: Biodegradable; metal stents; inflammation modulation; alloy design
Published: August 6, 2025
DOI: 10.54254/2753-8818/2025.AU25671
Volume: TNS Vol.133
pp. 90-100
Download PDF

References

  1. Dunbar SB, Khavjou OA, Bakas T, Hunt G, Kirch RA, Leib AR, et al. Projected Costs of Informal Caregiving for Cardiovascular Disease: 2015 to 2035: A Policy Statement From the American Heart Association. Circulation. 2018; 137(19): e558-e77.
  2. Bowen PK, Guillory RJ, Shearier ER, Seitz J-M, Drelich J, Bocks M, et al. Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents. Materials Science and Engineering: C. 2015; 56: 467-72.
  3. Udriște AS, Burdușel AC, Niculescu A-G, Rădulescu M, Grumezescu AM. Coatings for cardiovascular stents—an up-to-date review. International Journal of Molecular Sciences. 2024; 25(2): 1078.
  4. Zhang B, Wan H, Liu X, Yu T, Yang Y, Dai Y, et al. Engineering immunomodulatory stents using zinc ion–lysozyme nanoparticle platform for vascular remodeling. ACS nano. 2023; 17(23): 23498-511.
  5. Bowen PK, Drelich J, Goldman J. Zinc exhibits ideal physiological corrosion behavior for bioabsorbable stents. 2013.
  6. Bowen PK, Shearier ER, Zhao S, Guillory RJ, Zhao F, Goldman J, et al. Biodegradable metals for cardiovascular stents: from clinical concerns to recent Zn‐Alloys. Advanced healthcare materials. 2016; 5(10): 1121-40.
  7. Yang H, Wang C, Liu C, Chen H, Wu Y, Han J, et al. Evolution of the degradation mechanism of pure zinc stent in the one-year study of rabbit abdominal aorta model. Biomaterials. 2017; 145: 92-105.
  8. Li Y, Li Y, Bai Y. Improved the deposition rate of polydopamine on the biodegradable pure Zn via ZnO coating for cardiovascular stent application. Chemical Engineering Journal. 2023; 465: 142967.
  9. Gu X, Zheng Y, Cheng Y, Zhong S, Xi T. In vitro corrosion and biocompatibility of binary magnesium alloys. Biomaterials. 2009; 30(4): 484-98.
  10. Francis A, Yang Y, Virtanen S, Boccaccini A. Iron and iron-based alloys for temporary cardiovascular applications. Journal of Materials Science: Materials in Medicine. 2015; 26: 1-16.
  11. Liu B, Zheng Y, Ruan L. In vitro investigation of Fe30Mn6Si shape memory alloy as potential biodegradable metallic material. Materials letters. 2011; 65(3): 540-3.
  12. Lu S, Wang Q, Yao T, Feng H, Gao M, Xi T, et al. Simultaneous improvement of strength and plasticity: Nano-twin construction for a novel high-nitrogen TWIP steel. International Journal of Plasticity. 2024; 183: 104144.
  13. Quazi MM, A. FM, A. HASM, Farazila Y, H. MH, and Arslan A. Laser-based Surface Modifications of Aluminum and its Alloys. Critical Reviews in Solid State and Materials Sciences. 2016; 41(2): 106-31.
  14. Akhmedov S, Afanasyev S, Trusova M, Postnikov P, Rogovskaya Y, Grakova E, et al. Chemically modified biomimetic carbon-coated iron nanoparticles for stent coatings: in vitro cytocompatibility and in vivo structural changes in human atherosclerotic plaques. Biomedicines. 2021; 9(7): 802.
  15. Campeol DA, Fontoura CP, Rodrigues MM, Aguzzoli C. Assessment of mechanical and corrosion properties of plasma oxidized medical grade NiTi wire. Vacuum. 2020; 171: 109013.
  16. Zhang Z-Q, Yang Y-X, Li J-A, Zeng R-C, Guan S-K. Advances in coatings on magnesium alloys for cardiovascular stents – A review. Bioactive Materials. 2021; 6(12): 4729-57.
  17. Mao L, Zhu H, Chen L, Zhou H, Yuan G, Song C. Enhancement of corrosion resistance and biocompatibility of Mg-Nd-Zn-Zr alloy achieved with phosphate coating for vascular stent application. Journal of Materials Research and Technology. 2020; 9(3): 6409-19.
  18. McKittrick C, Cardona M, Black R, McCormick C. Development of a bioactive polymeric drug eluting coronary stent coating using electrospraying. Annals of biomedical engineering. 2020; 48(1): 271-81.
  19. Lakalayeh GA, Rahvar M, Nazeri N, Ghanbari H. Evaluation of drug-eluting nanoparticle coating on magnesium alloy for development of next generation bioabsorbable cardiovascular stents. Medical Engineering & Physics. 2022; 108: 103878.
  20. Xiong P, Yan J, Wang P, Jia Z, Zhou W, Yuan W, et al. A pH-sensitive self-healing coating for biodegradable magnesium implants. Acta biomaterialia. 2019; 98: 160-73.
  21. Vardhan V, Sharma A. In vitro degradation behavior of grain refined WE43 magnesium alloy for biodegradable temporary implant applications. Materialwissenschaft und Werkstofftechnik. 2024; 55(8): 1103-12.
  22. Mostaed E, Sikora-Jasinska M, Mostaed A, Loffredo S, Demir AG, Previtali B, et al. Novel Zn-based alloys for biodegradable stent applications: Design, development and in vitro degradation. J Mech Behav Biomed Mater. 2016; 60: 581-602.
  23. Hu W, Jiang J. Hypersensitivity and in-stent restenosis in coronary stent materials. Frontiers in Bioengineering and Biotechnology. 2022; 10: 1003322.
  24. Nakamura K, Kawakami T, Yamamoto N, Tomizawa M, Fujiwara T, Ishii T, et al. Activation of the NLRP3 inflammasome by cellular labile iron. Experimental hematology. 2016; 44(2): 116-24.
  25. Kwesiga MP, Gillette AA, Razaviamri F, Plank ME, Canull AL, Alesch Z, et al. Biodegradable magnesium materials regulate ROS-RNS balance in pro-inflammatory macrophage environment. Bioact Mater. 2023; 23: 261-73.
  26. Li J, Ren L, Zhang S, Ren G, Yang K. Cu-bearing steel reduce inflammation after stent implantation. Journal of Materials Science: Materials in Medicine. 2015; 26: 1-4.
  27. Peng Q, Li K, Han Z, Wang E, Xu Z, Liu R, et al. Degradable magnesium-based implant materials with anti-inflammatory activity. J Biomed Mater Res A. 2013; 101(7): 1898-906.
  28. Shen Y, Hu Y, Qiu L. Nano-vesicles based on phospholipid-like amphiphilic polyphosphazenes to orally deliver ovalbumin antigen for evoking anti-tumor immune response. Acta Biomaterialia. 2020; 106: 267-77.
  29. Wu J, Jin L, Tan JY, Chen XF, Wang QQ, Yuan GY, et al. The effects of a biodegradable Mg-based alloy on the function of VSMCs via immunoregulation of macrophages through Mg-induced responses. Ann Transl Med. 2021; 9(16): 1292.
  30. Jin L, Chen C, Li Y, Yuan F, Gong R, Wu J, et al. A Biodegradable Mg-Based Alloy Inhibited the Inflammatory Response of THP-1 Cell-Derived Macrophages Through the TRPM7-PI3K-AKT1 Signaling Axis. Front Immunol. 2019; 10: 2798.
  31. Holman H, Kavarana MN, Rajab TK. Smart materials in cardiovascular implants: Shape memory alloys and shape memory polymers. Artif Organs. 2021; 45(5): 454-63.
  32. Xiang E, Vaquette C, Liu S, Raveendran N, Schulz BL, Nowwarote N, et al. Biomimetic Surface Nanoengineering of Biodegradable Zn‐Based Orthopedic Implants for Enhanced Biocompatibility and Immunomodulation. Advanced Functional Materials. 2024; 34(51): 2410033.
  33. Kubow KE, Vukmirovic R, Zhe L, Klotzsch E, Smith ML, Gourdon D, et al. Mechanical forces regulate the interactions of fibronectin and collagen I in extracellular matrix. Nature communications. 2015; 6(1): 8026.
  34. Moravej M, Mantovani D. Biodegradable metals for cardiovascular stent application: interests and new opportunities. Int J Mol Sci. 2011; 12(7): 4250-70.
  35. Lenzuni M, Suarato G, Miele D, Carzino R, Ruggeri M, Bertorelli R, et al. Development of biodegradable zein-based bilayer coatings for drug-eluting stents. RSC Advances. 2021; 11(39): 24345-58.
  36. Liu J, Zhu H, Pei Y, Zhang H, Zhou J, Jing Z. A methylprednisolone-loaded and core-shell nanofiber-covered stent-graft to prevent inflammation and reduce degradation in aortic dissection. Biomater Res. 2022; 26(1): 15.