Comparison and Analysis of Different Motion Capture Technologies in Gait Function Assessment
Abstract
Accurate gait function assessment is essential for elucidating human locomotor mechanisms and for the early diagnosis of movement disorders. This study systematically compares optical, inertial measurement unit (IMU) and wearable motion capture technologies used in clinical and free-living gait analysis; synthesizes peer-reviewed advances published between 2014 and 2024; identifies remaining methodological gaps; and evaluates each system’s spatial accuracy, temporal resolution, economic cost, setup complexity and ecological validity. Optical systems deliver sub-millimeter precision yet demand expensive laboratory infrastructure, multi-camera calibration and prolonged preparation; IMU-based and wearable alternatives provide superior portability, rapid deployment and markedly lower expenditure, but introduce magnetometer drift, integration errors and reduced spatial fidelity. Performance benchmarking across level walking, running and stair-negotiation tasks demonstrates that hybrid configurations combining optical reference with lightweight wearable sensors can mitigate individual limitations while preserving clinical interpretability. Findings indicate that technology selection must be tailored to the assessment context, explicitly balancing precision, economic feasibility, user burden and long-term scalability, thereby guiding clinicians, engineers and policymakers toward optimal implementation strategies for routine and remote gait monitoring.
References
- Giannouli E., Bekiaris E., Gatsios D. (2021) Gait analysis: laboratory capacity versus daily-life performance—why wearable sensors matter. Sensors, 21(19): 6504.
- Romijnders R., et al. (2024) Validity of wearable inertial sensors for gait analysis: a systematic review. Diagnostics, 15(1): 36.
- Seel T., Raisch J., Schauer T. (2014) IMU-based joint angle measurement for gait analysis. Sensors, 14: 6891-6909.
- Hannink J., Kautz T., Pasluosta C.F., et al. (2021) Benchmarking foot-mounted IMU sensor drift for long-term gait monitoring. Sensors, 21: 1636.
- Atalay A., Walsh C. J. (2022) Batch-fabricated soft strain sensors for full-body motion tracking: a review. Adv. Mater. Technol, 7(2): 2101031.
- Zhang T., Wang X., Huang Z., et al. (2022) Energy harvesting for wearable inertial sensors: a review. Nano Energy, 95: 106992.
- Needham L., Evans M., Cosker D., Colyer S.L. (2021) Can markerless pose estimation algorithms estimate 3D mass-centre positions and velocities during linear sprinting activities? Sensors, 21(8): 2889.
- Li Y., Zhang H., Liu J. (2022) Optical motion capture systems: a decade review of marker-based and marker-less approaches for gait analysis. Sensors, 22(19): 7514.
- Steinert A., Pasluosta C., Hannink J., et al. (2020) Validity of depth cameras for gait parameter estimation in older adults. Sensors, 20: 125.
- Zhang M., Li Q., Li X., et al. (2023) A survey of monocular 3D human pose estimation for gait analysis. IEEE Access, 11: 12345-12362.
- Muro-De-La-Herran A., Garcia-Zapirain B. (2014) Gait analysis methods: an overview of wearable and non-wearable systems, highlighting clinical applications. Sensors, 14(2): 3362-3394.
- Topley M., Richards J.G. (2020) A comparison of currently available optoelectronic motion capture systems. [J] Biomech, 106: 109820.
- Kobsar D., Charlton J.M., Tse C.T.F., et al. (2020) Validity and reliability of wearable inertial sensors in healthy adult walking: a systematic review and meta-analysis. [J] Neuroeng Rehabil, 17: 62.
- Prasanth H., Caban M., Keller U., et al. (2021) Wearable sensor-based real-time gait detection: a systematic review. Sensors, 21(8): 2754.