Research Article

Dental Cone-Beam Computed Tomography Artifact Mechanisms and Mitigation Strategies

Zhiheng Zhang*
Shandong First Medical University & Shandong Academy of Medical Sciences

* Corresponding author: [email protected]

Abstract

Dental cone-beam computed tomography (CBCT) has been a prevalent diagnostic modality in implant planning and endodontic disease because it provides three-dimensional information. However, image quality is often compromised by artifacts, including streaks, bands, shadings and cupping, which result from scatter, beam hardening, photon starvation and metals. These artifacts can reduce contrast, distort gray values, and render fine anatomical details hard to interpret. Artifacts correction strategies are distributed in four steps along the imaging chain: acquisition, projection, reconstruction and post-processing. In general, projection-domain methods are proved to exert the biggest impact, particularly for metal-related artifacts. Additionally, assessment endpoints, CBCT systems and experimental objects varied across studies, making direct comparison of methods difficult. However, each approach demonstrated effectiveness for specific artifact types and imaging conditions. For future methods, powerful functions in spectral CT might be deployed in dental CBCT so that material decomposition and virtual monoenergetic imaging (VMI) can substantially reduce metal artifacts. This review aims to summarize the main artifact types and underlying mechanisms in dental CBCT, as well as evaluating the methods currently used for their mitigation.

Keywords: CBCT; scatter; beam-hardening; photon starvation; metal artifacts.
Published: April 28, 2026
DOI: 10.54254/2753-8818/2026.33015
Volume: TNS Vol.162
pp. 236-250
Download PDF

References

  1. Zhao, W., Vernekohl, D., Zhu, J., Wang, L., and Xing, L. (2016) A model-based scatter artifacts correction for cone beam CT. Medical Physics, 43(4), 1736–1753.
  2. Sawicki, P., Zawadzki, P. J., and Regulski, P. (2022) The impact of cone-beam computed tomography exposure parameters on peri-implant artifacts: A literature review. Cureus, 14(3), e23035.
  3. Zeng, G. L. (2022) Photon starvation artifact reduction by shift-variant processing. IEEE Access : Practical Innovations, Open Solutions, 10, 13633–13649.
  4. Parsa, A., Ibrahim, N., Hassan, B., Syriopoulos, K., and van der Stelt, P. (2014) Assessment of metal artefact reduction around dental titanium implants in cone beam CT. Dentomaxillofacial Radiology, 43(7), 20140019.
  5. Li, B., Somerkivi, V., Bayat, F., Huynh, C., and Altunbas, C. (2025) Effect of a prototype 2-dimensional antiscatter grid on image quality obtained with a dental cone-beam computed tomography scanner. Imaging Science in Dentistry, 55(1), 37–47.
  6. Sabounchi, R., Pyakurel, U., Bayat, F., Eldib, M., Ozus, B., Crockett, B., and Altunbas, C. (2025) Improving Hounsfield unit accuracy in dental CBCT through the integration of 2D anti-scatter grid. Oral Radiology, 41(4), 485–497.
  7. Hegazy, M. A. A., Cho, M. H., Cho, M. H., and Lee, S. Y. (2023) Metal artifact reduction in dental CBCT images using direct sinogram correction combined with metal path-length weighting. Sensors, 23(3), 1288.
  8. Shi, L., Bennett, N. R., Shiroma, A., Sun, M., Zhang, J., Colbeth, R., Star-Lack, J., Lu, M., and Wang, A. S. (2021) Single-pass metal artifact reduction using a dual-layer flat panel detector. Medical Physics, 48(10), 6482–6496.
  9. Ramage, A., Lopez Gutierrez, B., Fischer, K., Sekula, M., Santaella, G. M., Scarfe, W., Brasil, D. M., and de Oliveira-Santos, C. (2023) Filtered back projection vs. iterative reconstruction for CBCT: Effects on image noise and processing time. Dento Maxillo Facial Radiology, 52(8), 20230109.
  10. Choi, D.-I., Yun, S., Hyun, S., and Cho, S. (2025) Metal artifact reduction algorithm with conditional latent diffusion model for dental cone-beam CT. Journal of Applied Clinical Medical Physics, 26(11), e70317.
  11. Oliveira, M. L., Schaub, S., Dagassan-Berndt, D., Bieder, F., Cattin, P. C., and Bornstein, M. M. (2025) Development and evaluation of a deep learning model to reduce exomass-related metal artefacts in cone-beam CT: An ex vivo study using porcine mandibles. Dento Maxillo Facial Radiology, 54(2), 109–117.
  12. Li, B., Spronk, D., Luo, Y., Puett, C., Inscoe, C. R., Tyndall, D. A., Lee, Y. Z., Lu, J., and Zhou, O. (2022) Feasibility of dual-energy CBCT by spectral filtration of a dual-focus CNT x-ray source. PLoS ONE, 17(2), e0262713.
  13. Jayakody, D., Agrawal, H., Räinä, E., Sipola, A., Näpänkangas, R., Ylisiurua, S., Nieminen, M. T., and Brix, M. (2025) A hybrid approach combining dual-energy and inpainting methods for metal artifact reduction in dentomaxillofacial CBCT: A proof-of-concept phantom study. Annals of Biomedical Engineering, 53(10), 2638–2647.
  14. Zanon, C., Pepe, A., Cademartiri, F., Bini, C., Maffei, E., Quaia, E., Stellini, E., and Di Fiore, A. (2024) Potential benefits of photon-counting CT in dental imaging: A narrative review. Journal of Clinical Medicine, 13(8), 2436.