Research Article

Wearable Sensor Technology and its Applications in the Medical Field

Ruiyang Wen*
Beijing Luhe International Academy

* Corresponding author: [email protected]

Abstract

With the development of biomedical engineering and Internet of Things technology, wearable sensing technology plays an increasingly important role in the field of modern medicine. Wearable sensing technology is widely used in biomedical field because of its non-invasive and portable characteristics, especially in laboratory medicine. With the development of wearable sensing technology from traditional rigid structure to flexible patch, its sensitivity, specificity, stability and practicability have been greatly improved. Combined with related research, this study aims to systematically comb three different sensors, reveal the core principles of physical and chemical measurement sensors, and special sensors, and integrate their current applications in intensive care unit, pulse phase and acupuncture effect of traditional Chinese medicine and chronic disease management. This study is expected to provide theoretical reference for the clinical transformation of wearable sensing technology and promote the sustainable development of smart medical care and equipment safety.

Keywords: medical; sensor; biology; Traditional Chinese Medicine
Published: June 30, 2026
DOI: 10.54254/2753-8818/2026.AU34901
Volume: TNS Vol.177
pp. 204-211
Download PDF

References

  1. Wen H Ko& Yue Jincheng. (1987). Solid-state physical sensors for biomedical research. Foreign Medicine (Biomedical Engineering Volume), 10(01), 18-23.
  2. Nyein, H.Y.Y., Bariya, M., Tran, B.  et al.  A wearable patch for continuous analysis of thermoregulatory sweat at rest.  Nat Commun  12, 1823 (2021). https: //doi.org/10.1038/s41467-021-22109-z
  3. Yang Wenxin. (2025). Study on detection of biological signal molecules by photoelectrochemical sensor based on photocurrent polarity reversal (master's dissertation, Guangzhou University). Master's degree in https: //doi.org/10.27040/d.cnki.ggzdu.2025.000536.
  4. Li Yang, He Wang, Abu Musa Abdullah, Chuizhou Meng, Xue Chen, Anqi Feng, and Huanyu Cheng. (2023). ACS Applied Materials & Interfaces, 15 (29), 34332-34342. DOI: 10.1021/acsami.3c02485
  5. Mahan Hosseinzadeh Fakhr, Ivan Lopez Carrasco, Dmitry Belyaev, Jihun Kang, YeHyeon Shin, Jong-Souk Yeo, Won-Gun Koh, Jeongwoo Ham, Alexander Michaelis, Joerg Opitz, & Natalia Beshchasna. (2024). Recent advances in wearable electrochemical biosensors towards technological and material aspects. Biosensors and Bioelectronics: X, 19, 100503. https: //doi.org/10.1016/j.biosx.2024.100503
  6. Ran Yunde. (1998). Implanted biosensor for monitoring blood pH in vivo model. Aviation Military Medical, (06), 269-270.
  7. Lee, J., Liberty, L. M., Soltis, I., Kwon, K., Chong, D., Kwon, Y., & Yeo, W.-H. (2025). Wireless flexible potentiometric microsensors for temperature-compensated sweat electrolyte monitoring.  ACS Applied Materials & Interfaces, 17(25), 36345–36355.  https: //doi.org/10.1021/acsami.5c03558
  8. Huang, X., Zheng, S., Liang, B., He, M., Wu, F., Yang, J., Chen, H.-J., & Xie, X. (2023). 3D-assembled microneedle ion sensor-based wearable system for the transdermal monitoring of physiological ion fluctuations.  Microsystems & Nanoengineering, 9, 25.  https: //doi.org/10.1038/s41378-023-00497-0
  9. Molinero-Fernández, Á., Casanova, A., Wang, Q., Cuartero, M., & Crespo, G. A. (2023). In vivo transdermal multi-ion monitoring with a potentiometric microneedle-based sensor patch. ACS Sensors, 8(1), 158–166. https: //doi.org/10.1021/acssensors.2c01907
  10. Sang, M., Cho, M., Lim, S., Min, I. S., Han, Y., Lee, C., Shin, J., Yoon, K., Yeo, W. H., Lee, T., Won, S. M., Jung, Y., Heo, Y. J., & Yu, K. J. (2023). Fluorescent-based biodegradable microneedle sensor array for tether-free continuous glucose monitoring with smartphone application. Science Advances, 9(22), eadh1765.
  11. Shi, J., Xie, S., Liu, Z., Cai, M., & Guo, C. F. (2024). Non-hygroscopic ionogel-based humidity-insensitive iontronic sensor arrays for intra-articular pressure sensing. National Science Review, 11(11), nwae351.
  12. Bai, N., Xue, Y., Chen, S., Shi, L., Shi, J., Zhang, Y., Hou, X., Cheng, Y., Huang, K., Wang, W., Zhang, J., Liu, Y., & Guo, C. F. (2023). A robotic sensory system with high spatiotemporal resolution for texture recognition. Nature Communications, 14(1), 7121. https: //doi.org/10.1038/s41467-023-42722-4
  13. Louzon, P. R., Andrews, J. L., Torres, X., et al. (2020). Characterisation of ICU sleep by a commercially available activity tracker and its agreement with patient-perceived sleep quality. BMJ Open Respiratory Research, 7(1), e000572.
  14. Sharabi, I., Merin, R., Gluzman, Y., et al. (2023). Assessing the use of a noninvasive monitoring system providing multiple cardio-pulmonary parameters. Digital Health, 9, 20552076231179014.
  15. Turmell, M., Cooley, A., Yap, T. L., et al. (2022). Improving pressure injury prevention by using wearable sensors. American Journal of Critical Care, 31(4), 295–305.
  16. Davoudi, A., Malhotra, K. R., Shickel, B., et al. (2019). Intelligent ICU for autonomous patient monitoring. Scientific Reports, 9(1), 8020.
  17. Ma Yuliang, Wu Keke, Fang Dandong & Tong Zhihui. (2025). Research progress of wearable devices in intensive care unit. Medical research and treatment of war trauma, 38 (08), 880-885. https: //doi.org/10.16571/j.cnki.2097-2768.
  18. Wang Zheng, Mi Jinpeng & Chen Guodong. (2025). Application and development analysis of electronic skin in clinical diagnosis and treatment of traditional Chinese medicine. Journal of Electronics and Information, 47(08), 2486-2498.
  19. Jin Guanchang, Yu Miao, Bao Naikeng. (1999). Research on computer aided testing system of PVDF multipoint pulse wave. Journal of Tsinghua University (Natural Science Edition), (08), 118-121. https: //doi.org/10.16511/j.cnki.qhdxxb.
  20. Zhang Jian, Zhang Peng, Chen Yucheng, Li Yuxia & Huang Liangsong. (2021). Flexible capacitive pressure sensor based on paper-based electrode. Micro-nano electronic technology, 58 (03), 233-237+253. https: //doi.org/10.13250/J.