Research Article

Wearable Sensors for Physiological Monitoring: A Comprehensive Review

Zihan Gao*
Case Western Reserve University

* Corresponding author: [email protected]

Abstract

Wearable sensors are crucial for non-invasive and continuous health monitoring. The performance of these devices has been improved by recent advances in materials, device design and system integration. This review focuses on wearable sensors for physiological monitoring with special highlight on biophysical and biochemical sensing approaches. It discusses the ability of biochemical wearable sensors for biofluid biomarker analysis to provide molecular information to supplement physical measurements. Biophysical wearable sensors such as strain, pressure, temperature and bioelectrical sensors are also summarized. Their sensing mechanism and application in monitoring vital signs such as heart rate, respiratory rate, body temperature, blood oxygen saturation and cuffless blood pressure are discussed. The main challenges of wearable sensing including signal interference, interface stability, calibration and individual differences are also discussed. Finally, future directions of wearable sensor systems are highlighted with a focus on multimodal integration and translation towards clinically relevant and personalized health care applications.

Keywords: Wearable sensors; physiological monitoring; flexible materials; energy harvesting; healthcare
Published: June 30, 2026
DOI: 10.54254/2753-8818/2026.AU34966
Volume: TNS Vol.177
pp. 188-203
Download PDF

References

  1. Stoppa, M. and Chiolerio, A. (2014) Wearable Electronics and Smart Textiles: A Critical Review. Sensors. 14 (7), 11957–11992.
  2. Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., et al. (2018) Wearable sensors: modalities, challenges, and prospects. Lab on a Chip. 18 (2), 217–248.
  3. Yuan, Y., Liu, B., Li, H., Li, M., Song, Y., Wang, R., et al. (2022) Flexible Wearable Sensors in Medical Monitoring. Biosensors. 12 (12), 1069.
  4. Bariya, M., Nyein, H.Y.Y., and Javey, A. (2018) Wearable sweat sensors. Nature Electronics. 1 (3), 160–171.
  5. Kim, J., Campbell, A.S., De Ávila, B.E.-F., and Wang, J. (2019) Wearable biosensors for healthcare monitoring. Nature Biotechnology. 37 (4), 389–406.
  6. Shintake, J., Nagai, T., and Ogishima, K. (2019) Sensitivity Improvement of Highly Stretchable Capacitive Strain Sensors by Hierarchical Auxetic Structures. Frontiers in Robotics and AI. 6 127.
  7. Amjadi, M., Kyung, K., Park, I., and Sitti, M. (2016) Stretchable, Skin‐Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review. Advanced Functional Materials. 26 (11), 1678–1698.
  8. Zhao, S., Liu, D., and Yan, F. (2025) Wearable Resistive‐Type Stretchable Strain Sensors: Materials and Applications. Advanced Materials. 37 (5), 2413929.
  9. Nesser, H. and Lubineau, G. (2021) Strain Sensing by Electrical Capacitive Variation: From Stretchable Materials to Electronic Interfaces. Advanced Electronic Materials. 7 (10), 2100190.
  10. Cai, L., Song, L., Luan, P., Zhang, Q., Zhang, N., Gao, Q., et al. (2013) Super-stretchable, Transparent Carbon Nanotube-Based Capacitive Strain Sensors for Human Motion Detection. Scientific Reports. 3 (1), 3048.
  11. Cohen, D.J., Mitra, D., Peterson, K., and Maharbiz, M.M. (2012) A Highly Elastic, Capacitive Strain Gauge Based on Percolating Nanotube Networks. Nano Letters. 12 (4), 1821–1825.
  12. Wang, X., Deng, Y., Jiang, P., Chen, X., and Yu, H. (2022) Low-hysteresis, pressure-insensitive, and transparent capacitive strain sensor for human activity monitoring. Microsystems & Nanoengineering. 8 (1), 113.
  13. Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., et al. (2022) Wearable Pressure Sensors for Pulse Wave Monitoring. Advanced Materials. 34 (21), 2109357.
  14. Zang, Y., Zhang, F., Di, C., and Zhu, D. (2015) Advances of flexible pressure sensors toward artificial intelligence and health care applications. Materials Horizons. 2 (2), 140–156.
  15. Mishra, R.B., El‐Atab, N., Hussain, A.M., and Hussain, M.M. (2021) Recent Progress on Flexible Capacitive Pressure Sensors: From Design and Materials to Applications. Advanced Materials Technologies. 6 (4), 2001023.
  16. Tressler, J.F., Alkoy, S., and Newnham, R.E. (1998) Piezoelectric Sensors and Sensor Materials. Journal of Electroceramics. 2 (4), 257–272.
  17. Ferreira, R.G., Silva, A.P., and Nunes-Pereira, J. (2024) Current On-Skin Flexible Sensors, Materials, Manufacturing Approaches, and Study Trends for Health Monitoring: A Review. ACS Sensors. 9 (3), 1104–1133.
  18. Kim, J., Chou, E., Le, J., Wong, S., Chu, M., and Khine, M. (2019) Soft Wearable Pressure Sensors for Beat‐to‐Beat Blood Pressure Monitoring. Advanced Healthcare Materials. 8 (13), 1900109.
  19. Mannsfeld, S.C.B., Tee, B.C.-K., Stoltenberg, R.M., Chen, C.V.H.-H., Barman, S., Muir, B.V.O., et al. (2010) Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers. Nature Materials. 9 (10), 859–864.
  20. Chen, B., Feng, Z., Yao, F.-Z., Zhang, M.-H., Wang, K., Wei, Y., et al. (2025) Flexible piezoelectrics: integration of sensing, actuating and energy harvesting. Npj Flexible Electronics. 9 (1), 58.
  21. Daanen, H.A.M., Kohlen, V., and Teunissen, L.P.J. (2023) Heat flux systems for body core temperature assessment during exercise. Journal of Thermal Biology. 112 103480.
  22. Snyder, G.J. and Toberer, E.S. (2008) Complex thermoelectric materials. Nature Materials. 7 (2), 105–114.
  23. Xu, S., Zhang, Y., Jia, L., Mathewson, K.E., Jang, K.-I., Kim, J., et al. (2014) Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin. Science. 344 (6179), 70–74.
  24. Amendola, S., Bovesecchi, G., Palombi, A., Coppa, P., and Marrocco, G. (2016) Design, Calibration and Experimentation of an Epidermal RFID Sensor for Remote Temperature Monitoring. IEEE Sensors Journal. 16 (19), 7250–7257.
  25. Allen, J. (2007) Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement. 28 (3), R1–R39.
  26. Fortino, G. and Giampa, V. (2010) PPG-based methods for non invasive and continuous blood pressure measurement: an overview and development issues in body sensor networks. in: 2010 IEEE Int. Workshop Med. Meas. Appl., IEEE, Ottawa, ONpp. 10–13.
  27. Liu, J., Yan, B.P., Zhang, Y.-T., Ding, X.-R., Su, P., and Zhao, N. (2019) Multi-Wavelength Photoplethysmography Enabling Continuous Blood Pressure Measurement With Compact Wearable Electronics. IEEE Transactions on Biomedical Engineering. 66 (6), 1514–1525.
  28. Bent, B., Goldstein, B.A., Kibbe, W.A., and Dunn, J.P. (2020) Investigating sources of inaccuracy in wearable optical heart rate sensors. Npj Digital Medicine. 3 (1), 18.
  29. Shcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., et al. (2017) Accuracy in Wrist-Worn, Sensor-Based Measurements of Heart Rate and Energy Expenditure in a Diverse Cohort. Journal of Personalized Medicine. 7 (2), 3.
  30. Charlton, P.H., Kyriacou, P.A., Mant, J., Marozas, V., Chowienczyk, P., and Alastruey, J. (2022) Wearable Photoplethysmography for Cardiovascular Monitoring. Proceedings of the IEEE. 110 (3), 355–381.
  31. Ghamari, M. (2018) A review on wearable photoplethysmography sensors and their potential future applications in health care. International Journal of Biosensors & Bioelectronics. 4 (4), .
  32. Patel, S., Park, H., Bonato, P., Chan, L., and Rodgers, M. (2012) A review of wearable sensors and systems with application in rehabilitation. Journal of NeuroEngineering and Rehabilitation. 9 (1), 21.
  33. AlGhatrif, M. and Lindsay, J. (2012) A brief review: history to understand fundamentals of electrocardiography. Journal of Community Hospital Internal Medicine Perspectives. 2 (1), 14383.
  34. Chi, Y.M., Jung, T.-P., and Cauwenberghs, G. (2010) Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review. IEEE Reviews in Biomedical Engineering. 3 106–119.
  35. Dahiya, E.S., Kalra, A.M., Lowe, A., and Anand, G. (2024) Wearable Technology for Monitoring Electrocardiograms (ECGs) in Adults: A Scoping Review. Sensors. 24 (4), 1318.
  36. Nemati, E., Deen, M., and Mondal, T. (2012) A wireless wearable ECG sensor for long-term applications. IEEE Communications Magazine. 50 (1), 36–43.
  37. Searle, A. and Kirkup, L. (2000) A direct comparison of wet, dry and insulating bioelectric recording electrodes. Physiological Measurement. 21 (2), 271–283.
  38. Cretikos, M.A., Bellomo, R., Hillman, K., Chen, J., Finfer, S., and Flabouris, A. (2008) Respiratory rate: the neglected vital sign. Medical Journal of Australia. 188 (11), 657–659.
  39. Charlton, P.H., Birrenkott, D.A., Bonnici, T., Pimentel, M.A.F., Johnson, A.E.W., Alastruey, J., et al. (2018) Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review. IEEE Reviews in Biomedical Engineering. 11 2–20.
  40. Menuet, C., Ben-Tal, A., Linossier, A., Allen, A.M., Machado, B.H., Moraes, D.J.A., et al. (2025) Redefining respiratory sinus arrhythmia as respiratory heart rate variability: an international Expert Recommendation for terminological clarity. Nature Reviews Cardiology. 22 (12), 978–984.
  41. Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., and Schena, E. (2019) Contact-Based Methods for Measuring Respiratory Rate. Sensors. 19 (4), 908.
  42. Mukkamala, R., Hahn, J.-O., Inan, O.T., Mestha, L.K., Kim, C.-S., Toreyin, H., et al. (2015) Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice. IEEE Transactions on Biomedical Engineering. 62 (8), 1879–1901.
  43. Ding, X. and Zhang, Y.-T. (2019) Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm. Biomedical Engineering Letters. 9 (1), 37–52.
  44. Barvik, D., Cerny, M., Penhaker, M., and Noury, N. (2022) Noninvasive Continuous Blood Pressure Estimation From Pulse Transit Time: A Review of the Calibration Models. IEEE Reviews in Biomedical Engineering. 15 138–151.
  45. Xiao-Rong Ding and Yuan-Ting Zhang (2015) Photoplethysmogram intensity ratio: A potential indicator for improving the accuracy of PTT-based cuffless blood pressure estimation. in: 2015 37th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. EMBC, IEEE, Milanpp. 398–401.
  46. Muehlsteff, J., Aubert, X.A., and Morren, G. (2008) Continuous cuff-less blood pressure monitoring based on the pulse arrival time approach: The impact of posture. in: 2008 30th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., IEEE, Vancouver, BCpp. 1691–1694.
  47. Dehkordi, P., Khosrow-Khavar, F., Di Rienzo, M., Inan, O.T., Schmidt, S.E., Blaber, A.P., et al. (2019) Comparison of Different Methods for Estimating Cardiac Timings: A Comprehensive Multimodal Echocardiography Investigation. Frontiers in Physiology. 10 1057.
  48. Finnegan, E., Davidson, S., Harford, M., Watkinson, P., Tarassenko, L., and Villarroel, M. (2023) Features from the photoplethysmogram and the electrocardiogram for estimating changes in blood pressure. Scientific Reports. 13 (1), 986.
  49. Gulgosteren, E., Agrali Ermis, S., Algin Toros, A., Toros, T., Serin, E., Sekeroglu, M.O., et al. (2025) Sweat, tears, and beyond: advanced wearable sensors for personalized health and athletic performance. Frontiers in Bioengineering and Biotechnology. 13 1684674.
  50. Yali Zheng, Yan, B.P., Yuanting Zhang, Yu, C.M., and Poon, C.C.Y. (2013) Wearable cuff-less PTT-based system for overnight blood pressure monitoring. in: 2013 35th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. EMBC, IEEE, Osakapp. 6103–6106.
  51. Bandodkar, A.J. and Wang, J. (2014) Non-invasive wearable electrochemical sensors: a review. Trends in Biotechnology. 32 (7), 363–371.
  52. Heikenfeld, J., Jajack, A., Feldman, B., Granger, S.W., Gaitonde, S., Begtrup, G., et al. (2019) Accessing analytes in biofluids for peripheral biochemical monitoring. Nature Biotechnology. 37 (4), 407–419.
  53. Chen, S., Qiao, Z., Niu, Y., Yeo, J.C., Liu, Y., Qi, J., et al. (2023) Wearable flexible microfluidic sensing technologies. Nature Reviews Bioengineering. 1 (12), 950–971.
  54. Gao, W., Emaminejad, S., Nyein, H.Y.Y., Challa, S., Chen, K., Peck, A., et al. (2016) Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature. 529 (7587), 509–514.
  55. Ngamchuea, K., Chaisiwamongkhol, K., Batchelor-McAuley, C., and Compton, R.G. (2018) Chemical analysis in saliva and the search for salivary biomarkers – a tutorial review. The Analyst. 143 (1), 81–99.
  56. Ohashi, Y., Dogru, M., and Tsubota, K. (2006) Laboratory findings in tear fluid analysis. Clinica Chimica Acta. 369 (1), 17–28.
  57. Samant, P.P., Niedzwiecki, M.M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D.I., et al. (2020) Sampling interstitial fluid from human skin using a microneedle patch. Science Translational Medicine. 12 (571), eaaw0285.
  58. Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., et al. (2015) The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications. Biomicrofluidics. 9 (3), 031301.
  59. Mertz, L. (2022) Detecting Ion Levels, Changes to Monitor Health. IEEE Pulse. 13 (4), 14–19.
  60. Zhong, B., Jiang, K., Wang, L., and Shen, G. (2022) Wearable Sweat Loss Measuring Devices: From the Role of Sweat Loss to Advanced Mechanisms and Designs. Advanced Science. 9 (1), 2103257.
  61. Baker, L.B. (2017) Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability. Sports Medicine. 47 (S1), 111–128.
  62. Liu, L., Zhan, K., Kilpijärvi, J., Kinnunen, M., Zhao, Y., Zhang, Y., et al. (2026) Portable and label-free optical detection of sweat glucose using functionalized plasmonic nanopillar array. Microsystems & Nanoengineering. 12 (1), 43.
  63. Kwon, S.Y. and Moon, J.S. (2025) Advances in Continuous Glucose Monitoring: Clinical Applications. Endocrinology and Metabolism. 40 (2), 161–173.
  64. Ding, Y., Yang, L., Wen, J., Ma, Y., Dai, G., Mo, F., et al. (2025) A Comprehensive Review of Advanced Lactate Biosensor Materials, Methods, and Applications in Modern Healthcare. Sensors. 25 (4), 1045.
  65. Campbell, A.S., Kim, J., and Wang, J. (2018) Wearable electrochemical alcohol biosensors. Current Opinion in Electrochemistry. 10 126–135.
  66. Rocchitta, G., Spanu, A., Babudieri, S., Latte, G., Madeddu, G., Galleri, G., et al. (2016) Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids. Sensors. 16 (6), 780.
  67. Sonowal, K., Borthakur, P.P., and Pathak, K. (2025) Advances in Enzyme-Based Biosensors: Emerging Trends and Applications. in: IECB 2025, MDPI, p. 5.
  68. Manjakkal, L., Dervin, S., and Dahiya, R. (2020) Flexible potentiometric pH sensors for wearable systems. RSC Advances. 10 (15), 8594–8617.
  69. Chen, L., Chen, F., Liu, G., Lin, H., Bao, Y., Han, D., et al. (2022) Superhydrophobic Functionalized Ti3 C2 T x MXene-Based Skin-Attachable and Wearable Electrochemical pH Sensor for Real-Time Sweat Detection. Analytical Chemistry. 94 (20), 7319–7328.
  70. Rovira, M., Lafaye, C., Demuru, S., Kunnel, B.P., Aymerich, J., Cuenca, J., et al. (2024) Assessing the performance of a robust multiparametric wearable patch integrating silicon-based sensors for real-time continuous monitoring of sweat biomarkers. Biosensors and Bioelectronics. 262 116560.
  71. Jones, E.M., Cochrane, C.A., and Percival, S.L. (2015) The Effect of pH on the Extracellular Matrix and Biofilms. Advances in Wound Care. 4 (7), 431–439.
  72. Hajjar, S. and Zhou, X. (2023) pH sensing at the intersection of tissue homeostasis and inflammation. Trends in Immunology. 44 (10), 807–825.
  73. Levine, A., Zagoory-Sharon, O., Feldman, R., Lewis, J.G., and Weller, A. (2007) Measuring cortisol in human psychobiological studies. Physiology & Behavior. 90 (1), 43–53.
  74. Samson, C. and Koh, A. (2020) Stress Monitoring and Recent Advancements in Wearable Biosensors. Frontiers in Bioengineering and Biotechnology. 8 1037.
  75. Juliana, N., Maluin, S.M., Effendy, N.M., Abu, I.F., and Azmani, S. (2025) Cortisol Detection Methods and the Hormone's Role in Evaluating Circadian Rhythm Disruption. International Journal of Molecular Sciences. 26 (18), 9141.