Research Article

Advancements in Enhancing Degrees of Freedom for Upper-Limb Prostheses: Mechanisms, Control, and Sensory Feedback

Xuanxi Zhang*
Northeastern University

* Corresponding author: [email protected]

Abstract

Upper-limb amputation seriously affects a person's daily life. Traditional commercial myoelectric prostheses have only 2-6 degrees of freedom (DOFs) and are not yet capable of fine-motor manipulation. This paper reviews representative progress from 2014 to the first half of 2026 in three main directions: mechanism design and actuation, intelligent control and intention decoding, and sensory feedback and closed-loop interaction. The reviewed studies show that advanced mechanical configurations can add more active DOFs while reducing weight; deep learning decoding and shared semi-autonomous control can improve the accuracy and ease of control; and bidirectional neural interfaces, such as the e-OPRA system, have demonstrated the feasibility of closed-loop interaction. The analysis indicates that increasing the effective DOFs of prostheses requires the systematic integration of mechanisms, control and sensory feedback, rather than simply adding more joints.

Keywords: upper-limb prosthesis; degrees of freedom; myoelectric control; sensory feedback; neural interface
Published: October 13, 2026
DOI: 10.54254/2753-8818/2026.HZ37582
Volume: TNS Vol.198
pp. 9-19
Download PDF

References

  1. Belter, J. T., Segil, J. L., Dollar, A. M., et al. (2013). Mechanical design and performance specifications of anthropomorphic prosthetic hands: A review.Journal of Rehabilitation Research and Development, 50(5), 599–618. DOI: 10.1682/JRRD.2012.03.0052
  2. Belter, J. T., & Dollar, A. M. (2011). Performance characteristics of anthropomorphic prosthetic hands.2011 IEEE International Conference on Rehabilitation Robotics, 1–7. DOI: 10.1109/ICORR.2011.5975476
  3. Smit, G., Plettenburg, D. H., & van der Helm, F. C. (2015). The lightweight Delft Cylinder Hand: First multi-articulating hand that meets the basic user requirements.IEEE Transactions on Neural Systems and Rehabilitation Engineering, 23(3), 431–440. DOI: 10.1109/TNSRE.2014.2342158
  4. Farina, D., Jiang, N., Rehbaum, H., et al. (2014). The extraction of neural information from the surface EMG for the control of upper-limb prostheses: Emerging avenues and challenges.IEEE Transactions on Neural Systems and Rehabilitation Engineering, 22(4), 797–809. DOI: 10.1109/TNSRE.2014.2305111
  5. Scheme, E., & Englehart, K. (2011). Electromyogram pattern recognition for control of powered upper-limb prostheses: State of the art and challenges for clinical use.Journal of Rehabilitation Research and Development, 48(6), 643–659. DOI: 10.1682/JRRD.2010.09.0177
  6. Raspopovic, S., Capogrosso, M., Petrini, F. M., et al. (2014). Restoring natural sensory feedback in real-time bidirectional hand prostheses.Science Translational Medicine, 6(222), 222ra19. DOI: 10.1126/scitranslmed.3006820
  7. Piazza, C., Grioli, G., Catalano, M. G., et al. (2019). A century of robotic hands.Annual Review of Control, Robotics, and Autonomous Systems, 2, 1–32. DOI: 10.1146/annurev-control-060117-104956
  8. Cutkosky, M. R. (1989). On grasp choice, grasp models, and the design of hands for manufacturing tasks.IEEE Transactions on Robotics and Automation, 5(3), 269–279. DOI: 10.1109/70.34763
  9. Bullock, I. M., Zheng, J. Z., De La Rosa, S., et al. (2013). Grasp frequency and usage in daily household and machine shop tasks.IEEE Transactions on Haptics, 6(3), 296–308. DOI: 10.1109/TOH.2012.77
  10. Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002). Establishing a standardized clinical assessment tool of pathologic and prosthetic hand function: Normative data, reliability, and validity.Journal of Rehabilitation Research and Development, 39(1), 37–46.
  11. Mathiowetz, V., Volland, G., Kashman, N., et al. (1985). Adult norms for the Box and Block Test of manual dexterity.American Journal of Occupational Therapy, 39(6), 386–391. DOI: 10.5014/ajot.39.6.386
  12. Lyle, R. C. (1981). A performance test for assessment of upper limb function in physical rehabilitation treatment and research.International Journal of Rehabilitation Research, 4(4), 483–492.
  13. Keith, R. A., Granger, C. V., Hamilton, B. B., et al. (1987). The functional independence measure: A new tool for rehabilitation.Advances in Clinical Rehabilitation, 1, 6–18.
  14. Yang, H., Tao, Z., Yang, J., et al. (2025). A lightweight prosthetic hand with 19-DOF dexterity and human-level functions.Nature Communications, 16(1), 955. https://doi.org/10.1038/s41467-025-56352-5
  15. Godfrey, S. B., Zhao, K. D., Theuer, A., et al. (2018). The SoftHand Pro: Functional evaluation of a novel, flexible, and robust myoelectric prosthesis.PLoS ONE, 13(10), e0205653. https://doi.org/10.1371/journal.pone.0205653
  16. Resnik, L., Meucci, M. R., Lieberman-Klinger, S., et al. (2012). Advanced upper limb prosthetic devices: Implications for upper limb prosthetic rehabilitation.Archives of Physical Medicine and Rehabilitation, 93(4), 710–717. https://doi.org/10.1016/j.apmr.2011.11.010
  17. Sankar, S., Cheng, W. Y., Zhang, J., et al. (2025). A natural biomimetic prosthetic hand with neuromorphic tactile sensing for precise and compliant grasping.Science Advances, 11(10), eadr9300. https://doi.org/10.1126/sciadv.adr9300
  18. Da Silva, A. B. S., Mendes, G. E. P., Bragato, E. S., et al. (2024). Finger prosthesis driven by DEA pairs as agonist-antagonist artificial muscles.Biomimetics, 9(2), 110. https://doi.org/10.3390/biomimetics9020110
  19. Hou, L., Tang, R. Z., & Xu, Y. S. (2004). Review of theory, key technologies and its application of modular product design.Journal of Mechanical Engineering, 40(1), 56–61. DOI: 10.3321/j.issn:0577-6686.2004.01.012
  20. Atzori, M., Cognolato, M., & Müller, H. (2016). Deep learning with convolutional neural networks applied to electromyography data: A resource for the classification of movements for prosthetic hands.Frontiers in Neurorobotics, 10, 9. DOI: 10.3389/fnbot.2016.00009
  21. Hahne, J. M., Bießmann, F., Jiang, N., et al. (2014). Linear and nonlinear regression techniques for simultaneous and proportional myoelectric control.IEEE Transactions on Neural Systems and Rehabilitation Engineering, 22(2), 269–279. DOI: 10.1109/TNSRE.2014.2305520
  22. Kato, R., Fujita, T., Yokoi, H., et al. (2006). Adaptable EMG prosthetic hand using on-line learning method—Investigation of mutual adaptation between human and adaptable machine. InThe 15th IEEE International Symposium on Robot and Human Interactive Communication (RO-MAN)(pp. 599–604). IEEE. DOI: 10.1109/ROMAN.2006.314455
  23. Du, Y., Jin, W., Wei, W., et al. (2017). Surface EMG-based inter-session gesture recognition enhanced by deep domain adaptation.Sensors, 17(3), 458. DOI: 10.3390/s17030458
  24. Ketykó, I., Kovács, F., & Varga, K. Z. (2019). Domain adaptation for sEMG-based gesture recognition with recurrent neural networks. In2019 International Joint Conference on Neural Networks (IJCNN)(pp. 1–7). IEEE. DOI: 10.1109/IJCNN.2019.8852018
  25. Krasoulis, A., & Nazarpour, K. (2017). Improved prosthetic hand control with concurrent use of myoelectric and inertial measurements.Journal of NeuroEngineering and Rehabilitation, 14, 71. DOI: 10.1186/s12984-017-0284-9
  26. Markovic, M., Dosen, S., Popovic, D., et al. (2015). Sensor fusion and computer vision for context-aware control of a multi degree-of-freedom prosthesis.Journal of Neural Engineering, 12(6), 066022. DOI: 10.1088/1741-2560/12/6/066022
  27. Kuiken, T. A., Li, G., Lock, B. A., et al. (2009). Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms.JAMA, 301(6), 619–628. DOI: 10.1001/jama.2009.116
  28. Dumanian, G. A., Potter, B. K., Mioton, L. M., et al. (2019). Targeted muscle reinnervation treats neuroma and phantom pain in major limb amputees: A randomized clinical trial.Annals of Surgery, 270(2), 238–246. DOI: 10.1097/SLA.0000000000003088
  29. Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014). An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs.Science Translational Medicine, 6(257), 257re6. DOI: 10.1126/scitranslmed.3008933
  30. Mastinu, E., Doguet, P., Botquin, Y., et al. (2017). Embedded system for prosthetic control using implanted neuromuscular interfaces accessed via an osseointegrated implant.IEEE Transactions on Biomedical Circuits and Systems, 11(4), 867–877. DOI: 10.1109/TBCAS.2017.2694710
  31. Ortiz-Catalan, M., Mastinu, E., Sassu, P., et al. (2020). Self-contained neuromusculoskeletal arm prostheses.New England Journal of Medicine, 382(18), 1732–1738. DOI: 10.1056/NEJMoa1917537
  32. Antfolk, C., D'Alonzo, M., Rosén, B., et al. (2013). Sensory feedback in upper limb prosthetics.Expert Review of Medical Devices, 10(1), 45–54. DOI: 10.1586/erd.12.68
  33. George, J. A., Kluger, D. T., Davis, T. S., et al. (2019). Biomimetic sensory feedback through peripheral nerve stimulation improves dexterous use of a bionic hand.Science Robotics, 4(32), eaax2352. DOI: 10.1126/scirobotics.aax2352
  34. Vu, P. P., Vaskov, A. K., Irwin, Z. T., et al. (2020). A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees.Science Translational Medicine, 12(533), eaay2857. DOI: 10.1126/scitranslmed.aay2857