Brain-computer interfaces (BCIs) enable the brain to directly interact with external devices. At present, it has been applied in the fields of rehabilitation therapy, human-computer interaction and neuroscience research. However, different signal acquisition methods of BCI systems have significant differences in terms of invasiveness, signal quality, spatial and temporal resolution, and engineering implementation complexity. This paper focuses on three widely used brain-computer interface signal acquisition methods-electroencephalography (EEG), electrocorticography (ECoG) and intracortical recording-to compare and analyze the architecture and performance of their signal acquisition systems. Firstly, this paper introduces the basic signal processing link of BCI system and defines several key performance indicators. Then, the working principles of the three types of signal acquisition methods are analyzed respectively, and their performance is compared horizontally from the quantitative and qualitative levels. The comparison results show that from EEG to ECoG, and then to intracortical recording, the signal quality and spatial positioning accuracy are gradually increasing, but at the same time, the degree of system intrusion and the difficulty of engineering implementation are also increasing. The comparative analysis of this paper can provide a reference for researchers to select the appropriate signal acquisition scheme for specific brain-computer interface applications.

Keywords: BCI; EEG; ECoG; intracortical recording; signal acquisition
Published: October 20, 2026
DOI: 10.54254/2753-8818/2026.ES38044
Volume: TNS Vol.188
pp. 236-244
Download PDF

References

  1. Burnos, S., Fedele, T., Schmid, O., et al. (2016). Detectability of the somatosensory evoked high frequency oscillation (HFO) co-recorded by scalp EEG and ECoG under propofol.NeuroImage: Clinical, 10, 318–325.
  2. Wolpaw, J. R., Birbaumer, N., McFarland, D. J., et al. (2002). Brain-computer interfaces for communication and control.Clinical Neurophysiology, 113(6), 767–791.
  3. Flanagan, K., & Saikia, M. J. (2023). Consumer-grade electroencephalogram and functional near-infrared spectroscopy neurofeedback technologies for mental health and wellbeing.Sensors, 23(20), 8482.
  4. Harrison, R. R., & Charles, C. (2003). A low-power low-noise CMOS amplifier for neural recording applications.IEEE Journal of Solid-State Circuits, 38(6), 958–965.
  5. Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012). The origin of extracellular fields and currents—EEG, ECoG, LFP and spikes.Nature Reviews Neuroscience, 13(6), 407–420.
  6. Khodagholy, D., Gelinas, J. N., Thesen, T., et al. (2015). NeuroGrid: Recording action potentials from the surface of the brain.Nature Neuroscience, 18(2), 310–315.
  7. Musk, E., & Neuralink. (2019). An integrated brain-machine interface platform with thousands of channels.Journal of Medical Internet Research, 21(10), e16194.
  8. Parvizi, J., & Kastner, S. (2018). Human intracranial EEG: Promises and limitations.Nature Neuroscience, 21(4), 474–483.
  9. Burle, B., Spieser, L., Roger, C., et al. (2015). Spatial and temporal resolutions of EEG: Is it really black and white? A scalp current density view.International Journal of Psychophysiology, 97(3), 210–220.
  10. Schalk, G. (2010). Can electrocorticography (ECoG) support robust and powerful brain-computer interfaces?Frontiers in Neuroengineering, 3, 9.
  11. Katzner, S., Nauhaus, I., Benucci, A., et al. (2009). Local origin of field potentials in visual cortex.Neuron, 61(1), 35–41.
  12. Hashemi Noshahr, F., Nabavi, M., & Sawan, M. (2020). Multi-channel neural recording implants: A review.Sensors, 20(3), 904.