A Comparison of Marker-Based and AI-Driven Markerless Motion Capture Technologies for Orthopedic Gait Analysis: Accuracy, Limitations, and Clinical Applications
Abstract
Accurate assessment of human movement is crucial for identifying abnormal gait patterns and evaluating the effectiveness of orthopedic treatments. Meanwhile, advances in artificial intelligence and computer vision have promoted the development of markerless motion capture as an alternative to traditional marker-based systems. This paper primarily compares marker-based and AI-based markerless motion capture in orthopedic gait analysis, including their principles, errors, accuracy, and clinical applications. Marker-based systems have relatively high accuracy and are already well developed, but they can still be affected by soft tissue artifacts. Moreover, this system requires the pre-installation of markers before testing, and the equipment cost is also relatively high. While the markerless system does not need to attach markers to the body, it is therefore more convenient to use. Yet, limitations remain in complex 3D movements, pathological gait, and some dynamic measurements. Based on relevant research, this paper compares the features and application scenarios of the two technologies, and discusses their future development directions and their different roles in high-precision assessment and daily gait screening.
References
- Costa, R., Veloso, A., & Joao, F. (2026). Comparison of marker-based and markerless motion capture systems to assess gait kinematics and kinetics in children with cerebral palsy.Gait & Posture, 128, 110213. https://doi.org/10.1016/j.gaitpost.2026.110213
- Wade, L., Needham, L., McGuigan, P., & Bilzon, J. (2022). Applications and limitations of current markerless motion capture methods for clinical gait biomechanics.PeerJ, 10, e12995. https://doi.org/10.7717/peerj.12995
- Scataglini, S., Abts, E., Van Bocxlaer, C., Van den Bussche, M., Meletani, S., & Truijen, S. (2024). Accuracy, validity, and reliability of markerless camera-based 3D motion capture systems versus marker-based 3D motion capture systems in gait analysis: A systematic review and meta-analysis.Sensors, 24(11), 3686. https://doi.org/10.3390/s24113686
- Moro, M., Marchesi, G., Hesse, F., Odone, F., & Casadio, M. (2022). Markerless vs. marker-based gait analysis: A proof of concept study.Sensors, 22(5), 2011. https://doi.org/10.3390/s22052011
- Lam, W. W. T., Tang, Y. M., & Fong, K. N. K. (2023). A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation.Journal of NeuroEngineering and Rehabilitation, 20, 57. https://doi.org/10.1186/s12984-023-01186-9
- Ancillao, A., Aertbeliën, E., & De Schutter, J. (2021). Effect of the soft tissue artifact on marker measurements and on the calculation of the helical axis of the knee during a gait cycle: A study on the CAMS-Knee data set.Human Movement Science, 80, 102866. https://doi.org/10.1016/j.humov.2021.102866
- Scott, B., Seyres, M., Philp, F., Chadwick, E. K., & Blana, D. (2022). Healthcare applications of single camera markerless motion capture: A scoping review.PeerJ, 10, e13517. https://doi.org/10.7717/peerj.13517
- Wishaupt, K., Schallig, W., van Dorst, M. H., Buizer, A. I., & van der Krogt, M. M. (2024). The applicability of markerless motion capture for clinical gait analysis in children with cerebral palsy.Scientific Reports, 14, 11910. https://doi.org/10.1038/s41598-024-62119-7
- Poomulna, J., Knarr, B. A., Dutt, V., & Kingston, D. C. (2025). Comparison of gait deviation index (GDI) and gait variability index (GVI) measured by marker-based and markerless motion capture systems in children with cerebral palsy (CP).Gait & Posture, 115, 7–13. https://doi.org/10.1016/j.gaitpost.2024.10.018
- D'Souza, S., Siebert, T., & Fohanno, V. (2024). A comparison of lower body gait kinematics and kinetics between Theia3D markerless and marker-based models in healthy subjects and clinical patients.Scientific Reports, 14, 29154. https://doi.org/10.1038/s41598-024-80499-8