Research Article

Microneedle Sensors for Subcutaneous Biomarker Detection

Zhihan Guo*
Chongqing Yucai Secondary School

* Corresponding author: [email protected]

Abstract

Continuous monitoring of body chemistry is crucial for the management of chronic diseases such as diabetes, but blood draws and implanted sensor wires remain invasive, uncomfortable, and expensive for everyday use. The microneedle sensor is a micrometer-scale projection array that can penetrate the stratum corneum and the interstitial fluid (ISF) of the sample without touching the pain-sensing nerve endings, and it is a minimally invasive method for detecting subcutaneous biomarkers. This paper follows the thread that actually decides how such a device performs. The materials read like a trade-off table. Metal and silicon give dense, conductive arrays but stay rigid and pricey; polymers are cheap enough to throw away after use, yet bend; hydrogels load enzymes and dyes straight into the matrix, but respond slowly. The chemistry maps onto targets, not the other way around. Enzymatic amperometry still owns glucose and lactate; potentiometric membranes handle ions; aptamers and antibodies open the door to proteins and narrow-window drugs; fluorescent biodegradable patches let a smartphone read through the skin with nothing left behind. Building on these schemes, integrated patches now measure two metabolites at once in volunteers, dual glucose-and-metformin platforms report pharmacokinetic and pharmacodynamic feedback in diabetic animals, and disposable cartridges separate cheap consumables from reusable electronics. The remaining barrier is no longer device chemistry but longitudinal patient-grade validation and regulatory standardization. Closing this gap could turn microneedle patches into everyday closed-loop tools for personalized disease management.

Keywords: Microneedle sensors; interstitial fluid; wearable biosensors; biomarker detection; diabetes management
Published: November 17, 2026
DOI: 10.54254/2753-8818/2027.AD39000
Volume: TNS Vol.205
pp. 1-7
Download PDF

References

  1. Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., Mahato, K., Li, Z., Barfidokht, A., Yin, L., Warren, P., Huang, N., Patel, Z., Mercier, P. P., & Wang, J. (2022). An integrated wearable microneedle array for the continuous monitoring of multiple biomarkers in interstitial fluid.Nature Biomedical Engineering, 6(11), 1214–1224. https://doi.org/10.1038/s41551-022-00887-1
  2. Hu, Y., Chatzilakou, E., Pan, Z., Traverso, G., & Yetisen, A. K. (2024). Microneedle sensors for point-of-care diagnostics.Advanced Science (Weinheim, Baden-Wurttemberg, Germany), 11(12), e2306560. https://doi.org/10.1002/advs.202306560
  3. Zheng, M., Sheng, T., Yu, J., Gu, Z., & Xu, C. (2024). Microneedle biomedical devices.Nature Reviews Bioengineering, 2(4), 324-342. https://doi.org/10.1038/s44222-023-00141-6
  4. Moonla, C., Reynoso, M., Chang, A.-Y., Saha, T., Surace, S., & Wang, J. (2025). Microneedle-based multiplexed monitoring of diabetes biomarkers: Capabilities beyond glucose toward closed-loop theranostic systems.ACS Sensors, 10(8), 5363–5379. https://doi.org/10.1021/acssensors.5c00652
  5. Yang, J., Gong, X., Zheng, Y., Duan, H., Chen, S., Wu, T., Yi, C., Jiang, L., & Haick, H. (2025). Microneedle-based integrated pharmacokinetic and pharmacodynamic evaluation platform for personalized medicine.Nature Communications, 16(1), 6260. https://doi.org/10.1038/s41467-025-61549-9
  6. Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023). Wearable electrochemical glucose sensors in diabetes management: A comprehensive review.Chemical Reviews, 123(12), 7854–7889. https://doi.org/10.1021/acs.chemrev.3c00078
  7. Dervisevic, M., Alba, M., Adams, T. E., Prieto-Simon, B., & Voelcker, N. H. (2021). Electrochemical immunosensor for breast cancer biomarker detection using high-density silicon microneedle array.Biosensors & Bioelectronics, 192, 113496. https://doi.org/10.1016/j.bios.2021.113496
  8. Dervisevic, M., Alba, M., Yan, L., Senel, M., Gengenbach, T. R., Prieto-Simon, B., & Voelcker, N. H. (2022). Transdermal electrochemical monitoring of glucose via high-density silicon microneedle array patch.Advanced Functional Materials, 32(3), Article 2009850. https://doi.org/10.1002/adfm.202009850
  9. Sang, M., Cho, M., Lim, S., Min, I. S., Han, Y., Lee, C., Shin, J., Yoon, K., Yeo, W. H., Lee, T., Won, S. M., Jung, Y., Heo, Y. J., & Yu, K. J. (2023). Fluorescent-based biodegradable microneedle sensor array for tether-free continuous glucose monitoring with smartphone application.Science Advances, 9(22), eadh1765. https://doi.org/10.1126/sciadv.adh1765
  10. Lin, S., Cheng, X., Zhu, J., Wang, B., Jelinek, D., Zhao, Y., Wu, T.-Y., Horrillo, A., Tan, J., Yeung, J., Yan, W., Forman, S., Coller, H. A., Milla, C., & Emaminejad, S. (2022). Wearable microneedle-based electrochemical aptamer biosensing for precision dosing of drugs with narrow therapeutic windows.Science Advances, 8(38), eabq4539. https://doi.org/10.1126/sciadv.abq4539