Research Article

Design of ECG circuits for wearable devices

Guang Wu*
Zhongyuan University of Technology

* Corresponding author: [email protected]

Abstract

Heart diseases have become more and more prominent in recent years. ECG signals can accurately reflect the health of hearts during the detection process. The use of wearable ECG devices requires low power consumption, a high common-mode rejection ratio, and minimal noise. Traditional research has concentrated on lowering the circuit's overall power dissipation, which typically results in less current flowing through the amplifier but higher circuit noise. Therefore, this places higher demands on the amplifier in the circuit. Electronic devices are becoming smaller due to the rapid development of semiconductor technology. Amplifiers designed for semiconductor devices can effectively solve the problems mentioned above. The circuit created in this study has a low power need, a high common-mode rejection ratio, is compact, has a high input impedance, and has a low input-referred noise level. In addition, LT-Spice software was used to design and simulate the circuit, and the results were analyzed and calculated accordingly. The circuit meets the requirements of the project design. The frequency range of the circuit is 1mHz - 227.9Hz. The differential gain of the circuit is 36.6dB. The integrated input-fred noise is 3.94uV. The total consumption of electricity is 4.67W. These data indicate that the circuit has a high gain in the frequency range of ECG signals, which can filter out other interference signals. It also solves the problems of power consumption and noise.

Keywords: Wearable ECG Devices; Low Noise; Low Power Consumption; High Common-Mode Rejection Ratio
Published: November 30, 2023
DOI: 10.54254/2753-8818/13/20240836
Volume: TNS Vol.13
pp. 155-162
Download PDF

References

  1. Choi Y S, Hwang J, Lee M J, Lee J H and Youn H J 2023 Yonsei Med. J. 64 309
  2. Zhang Y P, Wang J P, Xiong D X and Guo L Q 2021 J. Transd. Microsyst. Technol. 40 73
  3. Gao M L 2019 J. Shanxi. Electron. Technol. 06 49
  4. Michele O, Stefan van D, William J Y, Julia R, Aled R J, Andrew T, Patricia B M and Pier D L 2023 J. Eur. Heart. J. - Dig. Health. 4 112
  5. Ma Q 2022 Research and Design of Low-power ECG Signal Acquisition Circuit Nanjing University of Posts and Telecommunications. 10.27251/d.cnki.gnjdc.2021.001101
  6. Wang T T 2021 Research on Wearable Continuous ECG Detection Analog Front-end Integrated Circuit. Guilin University of Electronic Technology. 10.27049/d.cnki.ggldc.2020.000121
  7. Ma Q, Zhang Y, Huang C H, Liu K 2021 Journal of Nanjing University of Posts and Telecommunications (Natural Science Edition) 41 72
  8. Li Z X 2023 Research and Design of Low-power and Low-noise Analog Front-end for Low-frequency and Low-amplitude Signals Guangzhou University. 10.27040/d.cnki.ggzdu.2023. 001647
  9. Ling X Y 2020 J. Electron. Test. 13 5
  10. Zhang Z 2021 Portable ECG Signals for Terminals Research on key Technologies of Acquisition Systems University of Electronic Science and Technology of China. 10.27005/d.cnki.gdzku. 2021.005020