Research Article

Non-invasive continuous imaging approaches to evaluate tissue structure and development

Yiyang Huang*
Rensselaer Polytechnic Institute

* Corresponding author: [email protected]

Abstract

As the field of tissue engineering advances toward fully functional organoids and artificially generated tissues, methods to evaluate the condition of the cultured tissue from the beginning to the end continuously grow more importance. The structure and developmental status of tissues in vivo reveal considerably more information than current approaches to discrete analysis like histology. Optical imaging modalities present a promising future regarding its ability to unveil morphological and biochemical changes of the tissue in a continuous manner without compromising its viability. Therefore, in this paper, several popular and emerging methods include Fluorescence Lifetime Imaging, Hyperspectral Imaging, Optical Coherence Microscopy, Light Sheet Fluorescence Microscopy, Near-infrared II Fluorescence Imaging, Mueller-matrix imaging are discussed with regards to their advantages and limitations in tissue engineering research. Although these approaches allow long term monitoring of developing tissue in vivo, they are not suitable in all conditions and lack spatial resolution and depth penetration. The potential of optical imaging on tissue structure and interactions can be further realized by improving upon fixed sample imaging techniques and utilizing multimodal systems.

Keywords: In-vivo imaging; fluorescence microscopy; optical microscopy; continuous monitoring; tissue engineering
Published: December 20, 2023
DOI: 10.54254/2753-8818/24/20231149
Volume: TNS Vol.24
pp. 172-177
Download PDF

References

  1. S. Y. Nam, L. M. Ricles, L. J. Suggs, and S. Y. Emelianov, “Imaging Strategies for Tissue Engineering Applications,” Tissue Engineering Part B: Reviews, vol. 21, no. 1, pp. 88–102, Aug. 2014. doi:10.1089/ten.teb.2014.0180
  2. P. K. Chandra, S. Soker, and A. Atala, “Tissue engineering: Current status and future perspectives,” Principles of Tissue Engineering, pp. 1–35, Apr. 2020. doi:10.1016/b978-0-12-818422-6.00004-6
  3. Datta R, Heaster TM, Sharick JT, Gillette AA, Skala MC. Fluorescence lifetime imaging microscopy: fundamentals and advances in instrumentation, analysis, and applications. J Biomed Opt. 2020 May;25(7):1-43. doi: 10.1117/1.JBO.25.7.071203.
  4. A. K. Haudenschild et al., “Non‐destructive detection of matrix stabilization correlates with enhanced mechanical properties of self‐assembled articular cartilage,” Journal of Tissue Engineering and Regenerative Medicine, vol. 13, no. 4, pp. 637–648, Mar. 2019. doi:10.1002/term.2824
  5. A. K. Haudenschild et al., “Non-destructive, continuous monitoring of biochemical, mechanical, and structural maturation in engineered tissue,” Scientific Reports, vol. 12, no. 1, Sep. 2022. doi:10.1038/s41598-022-18702-x
  6. E. H. Stelzer et al., “Light sheet fluorescence microscopy,” Nature Reviews Methods Primers, vol. 1, no. 1, Nov. 2021. doi:10.1038/s43586-021-00069-4
  7. M. Weber and J. Huisken, “In vivo imaging of cardiac development and function in zebrafish using light sheet microscopy,” Swiss Medical Weekly, Dec. 2015. doi:10.4414/smw.2015.14227
  8. Yang Z, Mei L, Xia F, Luo Q, Fu L, Gong H. Dual-slit confocal light sheet microscopy for in vivo whole-brain imaging of zebrafish. Biomed Opt Express. 2015 Apr 21;6(5):1797-811. doi: 10.1364/BOE.6.001797.
  9. Beghin, A., Grenci, G., Sahni, G. et al. Automated high-speed 3D imaging of organoid cultures with multi-scale phenotypic quantification. Nat Methods 19, 881–892 (2022). doi:10.1038/s41592-022-01508-0
  10. J. Cao et al., “Recent progress in NIR-II contrast agent for Biological Imaging,” Frontiers in Bioengineering and Biotechnology, vol. 7, Jan. 2020. doi:10.3389/fbioe.2019.00487
  11. Dang, X., Bardhan, N.M., Qi, J. et al. Deep-tissue optical imaging of near cellular-sized features. Sci Rep 9, 3873 (2019). doi:10.1038/s41598-019-39502-w
  12. Z. Lei and F. Zhang, “Molecular engineering of NIR‐II fluorophores for improved biomedical detection,” Angewandte Chemie International Edition, vol. 60, no. 30, pp. 16294–16308, Jul. 2021. doi:10.1002/anie.202007040
  13. Liu H, Hong G, Luo Z, Chen J, Chang J, Gong M, He H, Yang J, Yuan X, Li L, Mu X, Wang J, Mi W, Luo J, Xie J, Zhang XD. Atomic-Precision Gold Clusters for NIR-II Imaging. Adv Mater. 2019 Nov;31(46):e1901015. doi: 10.1002/adma.201901015.
  14. Antaris, A., Chen, H., Cheng, K. et al. A small-molecule dye for NIR-II imaging. Nature Mater 15, 235–242 (2016). doi:10.1038/nmat4476
  15. Aumann, S., Donner, S., Fischer, J., Müller, F. (2019). Optical Coherence Tomography (OCT): Principle and Technical Realization. In: Bille, J. (eds) High Resolution Imaging in Microscopy and Ophthalmology. Springer, Cham. doi:10.1007/978-3-030-16638-0_3
  16. Chen M, Feng Z, Fan X, Sun J, Geng W, Wu T, Sheng J, Qian J, Xu Z. Long-term monitoring of intravital biological processes using fluorescent protein-assisted NIR-II imaging. Nat Commun. 2022 Nov 4;13(1):6643. doi: 10.1038/s41467-022-34274-w.
  17. Yamanaka M, Hayakawa N, Nishizawa N. High-spatial-resolution deep tissue imaging with spectral-domain optical coherence microscopy in the 1700-nm spectral band. J Biomed Opt. 2019 Jul;24(7):1-4. doi: 10.1117/1.JBO.24.7.070502.
  18. Ash C, Dubec M, Donne K, Bashford T. Effect of wavelength and beam width on penetration in light-tissue interaction using computational methods. Lasers Med Sci. 2017 Nov;32(8):1909-1918. doi: 10.1007/s10103-017-2317-4. Epub 2017 Sep 12.
  19. Liu L, Gardecki JA, Nadkarni SK, Toussaint JD, Yagi Y, Bouma BE, Tearney GJ. Imaging the subcellular structure of human coronary atherosclerosis using micro-optical coherence tomography. Nat Med. 2011 Jul 10;17(8):1010-4. doi: 10.1038/nm.2409.
  20. Ang, M., Konstantopoulos, A., Goh, G. et al. Evaluation of a Micro-Optical Coherence Tomography for the Corneal Endothelium in an Animal Model. Sci Rep 6, 29769 (2016). doi:10.1038/srep29769
  21. C. Holmes, M. Tabrizian, and P. O. Bagnaninchi, “Motility imaging via optical coherence phase microscopy enables label-free monitoring of tissue growth and viability in 3D tissue-engineering scaffolds,” Journal of Tissue Engineering and Regenerative Medicine, vol. 9, no. 5, pp. 641–645, Feb. 2013. doi:10.1002/term.1687
  22. A. Le Gratiet, A. Mohebi, F. Callegari, P. Bianchini, and A. Diaspro, “Review on complete Mueller Matrix Optical Scanning Microscopy imaging,” Applied Sciences, vol. 11, no. 4, p. 1632, Jan. 2021. doi:10.3390/app11041632
  23. M. Mujat, R. D. Ferguson, and N. Iftimia, “Mueller Matrix Microscopy,” SPIE Proceedings, Apr. 2013. doi:10.1117/12.2024962
  24. S.-Y. Lu and R. A. Chipman, “Interpretation of Mueller matrices based on Polar decomposition,” Journal of the Optical Society of America A, vol. 13, no. 5, p. 1106, 1996. doi:10.1364/josaa.13.001106
  25. S. Alali and A. Vitkin, “Polarized light imaging in biomedicine: Emerging Mueller Matrix methodologies for bulk tissue assessment,” Journal of Biomedical Optics, vol. 20, no. 6, p. 061104, Mar. 2015. doi:10.1117/1.jbo.20.6.061104
  26. N. Ghosh, “Polarization birefringence measurements for characterizing the myocardium, including healthy, infarcted, and stem-cell-regenerated tissues,” Journal of Biomedical Optics, vol. 15, no. 4, p. 047009, Jul. 2010. doi:10.1117/1.3469844
  27. Jütte L, Roth B. Mueller Matrix Microscopy for In Vivo Scar Tissue Diagnostics and Treatment Evaluation. Sensors (Basel). 2022 Dec 1;22(23):9349. doi: 10.3390/s22239349.